Service and maintenance
9.2 Technical support
58
Power on transmitter
1.2.1
Transmitter OK
Check application
Check installation/sensor/earthing
connection etc.
1.2.2
Check cables/conndections
Check connection board
Check pins in transmitter multiplug
OK ⇒ 1.2.1
Not OK ⇒ correct fault
2
Check cables/conndections
Check connection board
Check pins in transmitter multiplug
OK ⇒ 2.1
Not OK ⇒ Correct fault
2.1
Output readings OK?
Yes ⇒ 2.1.1
No ⇒ 2.1.2.
2.1.1
Dispaly defective
Replace display
2.1.2
Transmitter defective
Replace transmitter
Note
Sensor check list
Check list for sensors are included in the respective sensor operating instructions.
9.2
Technical support
NOTICE
Repair and service must be carried out by approved Siemens Flow Instruments personnel
only.
Note
Siemens Flow Instrument defines sensors as non-repairable products.
Technical Support
If you have any technical questions about the device described in these Operating
Instructions and do not find the right answers, you can contact Technical Support:
●
Via the Internet using the Support Request:
Support request (
http://www.siemens.com/automation/support-request
●
Phone: +49 (0) 180 5050 222
Further information about our technical support is available in the Internet at
Technical support (
http://support.automation.siemens.com/WW/view/en/16604318
www.eltra-trade.com [email protected]
+421 552 601 099
Summary of Contents for SITRANS F M MAG 5000
Page 1: ...SITRANS F M MAG 5000 6000 Manual www eltra trade com info eltra trade com 421 552 601 099 ...
Page 9: ...Table of contents 6 www eltra trade com info eltra trade com 421 552 601 099 ...
Page 93: ......
Page 103: ...www eltra trade com info eltra trade com 421 552 601 099 ...
Page 105: ...Approvals Certificates 102 www eltra trade com info eltra trade com 421 552 601 099 ...