Description, device design, dimension drawing
2.2 Connections and terminal designation
SITOP SEL1200-1400
Manual, 06.2019, A5E46496083-1-76
11
2.2
Connections and terminal designation
The input terminals
①
can be used to establish the connection to the supply voltage. The
"0 V" connection
②
is used to supply the internal electronics. The output terminals
③
are
used to connect to the loads to be supplied (see also Chapter Installation (Page 33)).
The operating state of the device can be processed using the group signal contact
④
(for
the function and content rating, see Figure 2-4 Status displays and signaling (Page 13)).
The remote reset (RST) input
④
is used to reset outputs that have automatically been shut
down (function, see Chapter Status displays and signaling (Page 13)).
Connections and terminal designations
①
24 V DC input
2 spring-loaded terminals
②
0 V connection for the internal supply
2 spring-loaded terminals
③
24 V DC output: 1 - 8
one spring-loaded terminal each
④
Group signaling contact (13, 14); not assigned (NF);
remote reset (RST)
one spring-loaded terminal each
*1)
Do not subject the end stop to higher loads
Figure 2-2
Terminal data
NOTICE
Overload of the wiring
The "0 V" connection is only used to supply the internal electronics of the selectivity
module. The 0 V of the connected loads must be routed directly to the power supply using
separate cables!
Summary of Contents for SITOP SEL1200
Page 8: ...Safety instructions SITOP SEL1200 1400 8 Manual 06 2019 A5E46496083 1 76 ...
Page 26: ...Mounting removal SITOP SEL1200 1400 26 Manual 06 2019 A5E46496083 1 76 ...
Page 46: ...Safety approvals EMC 7 3 EMC SITOP SEL1200 1400 46 Manual 06 2019 A5E46496083 1 76 ...
Page 48: ...Ambient conditions SITOP SEL1200 1400 48 Manual 06 2019 A5E46496083 1 76 ...
Page 50: ...Environment SITOP SEL1200 1400 50 Manual 06 2019 A5E46496083 1 76 ...