11.2.3
Connecting
11.2.3.1
Interface overview
3RZHUVXSSO\
7HUPLQDOVWULSFRQYHUWHU
5LEERQFDEOH
352),1(7FDEOH
'LJLWDO,2
3RUWDQG
33'31
9'&
352),1(7;
;
;
;
;
1&8[
33'31
0&3&&31
Figure 11-10
I/O module connection options
Table 11-12 PP 72/48D PN I/O module interfaces
Interface
Designation
Type
Power supply connection
X1
Screw-terminal block
PROFINET IO
X2 (ports 1 and 2)
Socket
PROFINET address
S1
DIP switch
Digital input/outputs 1
X111
Ribbon cable connector
Digital input/outputs 2
X222
Ribbon cable connector
Digital input/outputs 3
X333
Ribbon cable connector
11.2.3.2
X1 power supply
Properties
This interface is intended exclusively for the connection of the external 24 V power supply.
On the module side, the power supplies are protected against:
● Polarity reversal
● Short-circuit (elec. current limitation of the outputs)
● Overload (self-restoring PTC fuse - Multifuse)
Connectable components
11.2 PP 72/48D PN
NCU 1760
108
Equipment Manual, 02/2020, A5E45627861B AB
Summary of Contents for SINUMERIK ONE NCU 1760
Page 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Page 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Page 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Page 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...