Interface overview
Table 7-1
Overview of the interfaces that can be used
Interface
Designation
Connector type
DRIVE-CLiQ
X100 - X105
Spec. RJ45 socket
Digital inputs/outputs
X122, X132, X142
3x14-pole spring-loaded terminals
24 VDC power supply
X124
Screw-type terminals, 4-pin
PROFINET
X150; port 1, 2
X160; port 1
Standard RJ45 socket
Ethernet IE1/OP
X120
Standard RJ45 socket, not suitable
for PoE
Ethernet IE2/NET
X130
Standard RJ45 socket, not suitable
for PoE
PROFIBUS DP1
X126
9-pin SUB-D socket
USB
X125, X135
Double SuperSpeed, type A socket
Ethernet (service socket)
X127
Standard RJ45 socket, not suitable
for PoE
SD card
X55
SD standard slot
Service socket
X140
DisplayPort socket
Dual fan module
X190
10-pin
Note
Interface X140 is only designed for service purposes, and cannot be used to connect a display.
7.2
Communication services and used port numbers
SINUMERIK supports the protocols listed in the following tables. The address parameters, the
relevant communication layer as well as the communication role and the communication
direction are specified for each protocol.
This information allows you to match the security measures for the protection of the automation
system to the used protocols (e.g. firewall).
The following table shows a section of the various layers and protocols that are used.
Connecting
7.2 Communication services and used port numbers
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB
51
Summary of Contents for SINUMERIK ONE NCU 1760
Page 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Page 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Page 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Page 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...