Parameter
Value
Resolution
16 bits (including sign)
Accuracy
+/- 0,5 %
Internal resistance Ri
133 ohm
Table 11-50 Technical data in the "PT100" operating mode
Parameter
Value
Input range (rated value)
- 200 ℃ to + 259 ℃
Standard
EN60751
Resolution
16 bits (including sign)
Accuracy
+/- 2 ℃
Internal resistance Ri
>> 10 kOhm
Note
If the PT100 operating mode is selected, the hardware is protected against overvoltage.
In the event of an error the following occurs:
1. An error bit is set which is then communicated to the PLC.
2. The module is shut down.
Measurement using a 4-wire connection system
Notes regarding the connection and operation of PT100 resistors:
This enables the module to supply X3 with a constant current via the CO1, CI1, CO2 and CI2
terminals. The constant current is fed to the resistor to be measured where it is then measured
as the voltage drop. It is imperative to wire the connected constant current cables directly to the
resistor.
Measurements with 4-wire connections compensate for line resistances and return a
considerably higher degree of precision in comparison with 2-wire connections.
Connectable components
11.3 PP 72/48D PN 2/2A PN
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB
139
Summary of Contents for SINUMERIK ONE NCU 1760
Page 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Page 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Page 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Page 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...