DRIVE-CLiQ interfaces X100 - X103
Table 12-4
Characteristics of X100 - X103
Characteristic
Version
Connector type
DRIVE-CLiQ connector
Cable type
DRIVE-CLiQ standard (inside the control cabinet)
MOTION-CONNECT (outside the control cabinet)
Max. cable length
70 m
Table 12-5
Pin assignment, X100 - X103
Pin
Signal name
Technical specifications
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4
-
Reserved, do not use
5
-
Reserved, do not use
6
RXN
Receive data -
7
-
Reserved, do not use
8
-
Reserved, do not use
A
+ (24 V)
Power supply
B
M (0 V)
Ground
DRIVE-CLiQ topology
NX components can be connected to the NCU via DRIVE-CLiQ. The following rules apply for the
wiring:
• Only one star topology is permitted between the NX and the NCU. In this way, only one NX
can be operated per DRIVE-CLiQ port of an NCU.
• DRIVE-CLiQ ports not assigned to NX can be wired to other DRIVE-CLiQ components.
• Once an NX has been connected and configured, you cannot simply insert it into a different
DRIVE-CLiQ port, as the addresses of the integrated drives are set permanently from the point
of view of the PLC. The following table illustrates this relation:
Table 12-6
NX PROFIBUS addresses
DRIVE-CLiQ port on the NCU
Drive PROFIBUS addresses
X103
13
X102
12
X101
11
X100
-
The following figure shows a sample topology:
Connectable components
12.1 NX10.3/NX15.3
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
105