4 Monitoring Functions
01.93
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
3081
”CRC not selected for approach”
Remedy:
CRC must have been selected before approach
Alarm No.
Alarm Text:
3082
”Feed missing/not prog.”
Explanation:
Remedy:
1.
During simulation of a part program
–
No feed F programmed
–
F value too small (MD).
2.
A feed type other than G98 has been programmed in a program
section with G36.
Program feed correctly.
Alarm No.
Alarm Text:
3083
”Feed limit fictitious axis”
Explanation:
Remedy:
So that the rotary axis does not travel faster in the TRANSMIT function
that defined in MD 280*, the feed is reduced for individual blocks, if
necessary.
The alarm does not occur during rapid traverse in the part program
(G00, G10).
Use feed override.
Alarm No.
Alarm Text:
3084
”Wrong data in DB 39”
Explanation:
Remedy:
– R parameter No. not in the permissible area
– Assignment of axis to cam parameter wrong.
Correct DB 39 values and perform value transfer.
Alarm No.
Alarm Text:
3087
”Transformation data error”
Explanation:
Incorrect content in the transformation MD.
The alarm applies to an individual block. The number of the incorrect
machine data (MD) is specified in the block number.
Alarm No.
Alarm Text:
3200
”Illegal working area limitation”
Reason:
Remarks:
Values were entered in the setting data (300*, 304*) which lie outside
the traverse range.
The control enters the permissible maximum or minimum value in the
setting data.
4-32
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)