4 Monitoring Functions
11.90
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
2072
”Incorrect input value”
Reason:
Effect:
Remedy:
The input value for the contour path calculation cannot be calculated.
The faulty block is not simulated or executed.
Input the correct value for the contour path
Alarm No.
Alarm Text:
2073
”No intersection point”
Reason:
Effect:
Remedy:
Calculation of the contour path gives no intersection point with the
values programmed.
As for alarm 2072
As for alarm 2072
Alarm No.
Alarm Text:
2074
”Incorrect angle value”
Reason:
Effect:
Remedy:
– An angle greater than or equal to 360 degrees was programmed
– The angle value has no meaning for the described contour
As for alarm 2072
As for alarm 2072
Alarm No.
Alarm Text:
2075
”Incorrect radius value”
Reason:
Effect:
Remedy:
– Radius value too large
– Radius value not allowed for the described contour
As for alarm 2072
As for alarm 2072
Alarm No.
Alarm Text:
2076
”Incorrect G02 / G03”
Reason:
Effect:
Remedy:
Direction of circle for the described contour is not possible
As for alarm 2072
As for alarm 2072
Alarm No.
Alarm Text:
2077
”Incorrect block sequence”
Reason:
Effect:
Remedy:
Several blocks are needed for the calculation of the contour path:
– Block sequence not correct
– Insufficient information (underdefined)
As for alarm 2072
As for alarm 2072
4-20
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)