Basic Operator Panel 20 (BOP20)
Operating Instructions, 11/2017, A5E00809375A
19
Setting parameters with the BOP20
4
4.1
BOP20 overview
Overview of displays and keys
Figure 4-1
Overview of displays and keys
Information on the displays
Table 4- 1
Displays/indicators
Display
Meaning
Top left, 2 chars.
The active drive object of the BOP is displayed here.
The displays and key operations always refer to this drive object.
RUN
Lit if at least one drive in the drive line-up is in the RUN state (in operation).
RUN is also displayed via bit r0899.2 of the drive.
Top right, 2 chars.
The following is displayed in this field:
•
More than 6 digits: Characters that are present but cannot be seen (e.g. "r2" ––> 2 char-
acters to the right are invisible, "L1" ––> 1 character to the left is invisible)
•
Faults: Selects/displays other drives with faults
•
Designation of BICO inputs (bi, ci)
•
Designation of BICO outputs (bo, co)
•
Source object of a BICO interconnection to a drive object other than the active one.
S
Lit if at least one parameter was changed and the value was not transferred to the non-
volatile memory.
P
Lit if the parameter value does not become effective until the P key is pressed.
C
Lit if at least one parameter was changed and the calculation for consistent data manage-
ment has still not been initiated.
Bottom, 6 chars.
Displays parameters, indices, faults, and alarms.