8.7
faults
8.7.1
Inspections in the event of faults
Natural disasters or unusual operating conditions, such as overloading or short circuit, are faults
that overload the machine electrically or mechanically.
Immediately perform an inspection after such faults.
Correct the cause of the fault as described in the respective remedial measures section. Repair
any damage to the machine.
8.7.2
Electrical faults
Note
If you are operating the motor with a converter, the operating instructions of the converter must
also be complied with if electrical faults occur.
Table 8-1
Electrical faults
↓ Motor fails to start
↓ Motor accelerates sluggishly
↓ Rumbling noise during startup
↓ Rumbling noise during operation
↓ High temperature rise during no-load operation
↓ High temperature rise with load
↓ High temperature rise of individual winding sections
Possible causes of faults
Remedial measures
X
X
X
X
Overload
Reduce the load.
X
Interrupted phase in the supply cable
Check frequency converters and supply cables.
X
X
X
X
Interrupted phase in the feeder cable af‐
ter switching on
Check frequency converters and supply cables.
X
Output voltage at the converter too low,
frequency too high
Check the settings at the converter (U/f).
X
Output voltage at the converter too high,
frequency too low
Check the settings at the converter (U/f).
X
X
X
X
X Stator winding incorrectly connected
Check the winding connection in the terminal
box.
X
X
X
X Winding short circuit or phase short cir‐
cuit in stator winding
Determine the winding resistances and insulation
resistances. Repair this after prior consultation
with the manufacturer.
X
Incorrect direction of rotation
Check the connection.
Operation
8.7 faults
1FU9
86
Operating Instructions, 07/2020, A5E46712792A
Summary of Contents for SIMOTICCS A 1FU9
Page 1: ...Operating Instructions 1FU9 SIMOTICS A 07 2020 Edition Synchronous motors www siemens com ...
Page 2: ......
Page 58: ...Assembly 5 6 Installing the machine 1FU9 56 Operating Instructions 07 2020 A5E46712792A ...
Page 80: ...Commissioning 7 3 Switching on 1FU9 78 Operating Instructions 07 2020 A5E46712792A ...
Page 110: ...Spare parts 1FU9 108 Operating Instructions 07 2020 A5E46712792A ...
Page 120: ...Technical data B 1 Tightening torques 1FU9 118 Operating Instructions 07 2020 A5E46712792A ...
Page 124: ...Index 1FU9 122 Operating Instructions 07 2020 A5E46712792A ...
Page 125: ......