3.3.3
Cooling and ventilation
The motors of this series are permanent-magnet synchronous motors with a closed primary
(internal) cooling circuit and an open secondary cooling circuit (surface cooling). The surface
cooling varies depending on the version.
3.3.3.1
Machines with a fan
Self-ventilation (standard): Cooling method IC 411 according to EN / IEC 60034-6
Located at the ND end of the stator housing is an air intake cowl that guides the external air on
its way to the motor. The external air is drawn in through openings in the air intake cowl and
flows axially across the outer cooling ribs of the motor frame. The fan wheel for the external
flow of cooling air is attached to the machine shaft.
The fan wheels are bidirectional.
Check the cooling effect below rated speed in the case of frequent switching or braking – or if
the speed is controlled continually below the rated speed.
,&,&$$
Forced ventilation (optional): Type of cooling IC 416 in accordance with EN / IEC 60034-6
Cooling that does not depend on the speed is achieved by means of a unit that is independent
of the motor operating state (forced ventilation). This unit is closed to the outside by a fan cover.
It has its own main drive with fan impeller which creates the cooling air flow required for cooling
the motor.
,&,&$$
Description
3.3 Installation
1FU9
22
Operating Instructions, 07/2020, A5E46712792A
Summary of Contents for SIMOTICCS A 1FU9
Page 1: ...Operating Instructions 1FU9 SIMOTICS A 07 2020 Edition Synchronous motors www siemens com ...
Page 2: ......
Page 58: ...Assembly 5 6 Installing the machine 1FU9 56 Operating Instructions 07 2020 A5E46712792A ...
Page 80: ...Commissioning 7 3 Switching on 1FU9 78 Operating Instructions 07 2020 A5E46712792A ...
Page 110: ...Spare parts 1FU9 108 Operating Instructions 07 2020 A5E46712792A ...
Page 120: ...Technical data B 1 Tightening torques 1FU9 118 Operating Instructions 07 2020 A5E46712792A ...
Page 124: ...Index 1FU9 122 Operating Instructions 07 2020 A5E46712792A ...
Page 125: ......