Motor Description
1.7 Electrical connections
1PH7/1-26
Siemens AG, 2004. All rights reserved
Induction Motors, 1PH7 (APH7S) – 05.04 Edition
Assignment, terminal boxes and max. cross-section
Table 1-9
Terminal box assignment, max. cable cross-sections that can be connected
Shaft
height
Motor type
Terminal box type
Number
of main terminals
Max. connectable cross-
section per terminal [mm
2
]
100
1PH710
-2
integrated
6 x M5
25
132
1PH713
-2
integrated
6 x M6
35
160
1PH716
-2
integrated
6 x M6
50
1PH7184-2
1XB7322
3 x M12
2 x 50
1PH7184-2
B
1XB7322
3 x M12
2 x 50
1PH7184-2
D
1XB7322
3 x M12
2 x 50
180
1PH7184-2
F
1XB7422
3 x M12
2 x 70
180
1PH7184-2
L
1XB7422
3 x M12
2 x 70
1PH7186-2
E
1XB7322
3 x M12
2 x 50
1PH7186-2
D
1XB7322
3 x M12
2 x 50
1PH7186-2
T
1XB7322
3 x M12
2 x 50
1PH7224-2
C
1XB7322
3 x M12
2 x 50
225
1PH7224-2
D
1XB7322
3 x M12
2 x 50
1PH7224-2
F
1XB7322
3 x M12
2 x 50
1.7.3
Supply data for separately-driven fans
Table 1-10
Supply data for separately-driven fans
Shaft height
[
mm
]
Air flow direction
Max. current drain at
400 V/50 Hz
(
10%)
400 V/60 Hz
(
10%)
480 V/60 Hz
(+5%, –10%)
DE ––> NDE
0.20
0.13
0.20
100
NDE ––> DE
0.19
0.13
0.18
DE ––> NDE
0.37
0.24
0.33
132
NDE ––> DE
0.35
0.24
0.32
DE ––> NDE
0.30
0.33
0.34
160
NDE ––> DE
0.29
0.31
0.33
DE ––> NDE
0.8
1.1
1.1
180
NDE ––> DE
0.8
1.1
1.1
DE ––> NDE
2.8
2.8
2.8
225
NDE ––> DE
1.9
2.2
2.2
Summary of Contents for Simodrive 1PH7
Page 1: ...Planning Guide 05 2004 Edition simodrive Induction Motors 1PH7 Main Spindle Drives ...
Page 2: ......
Page 173: ......
Page 175: ......