Motor Components
3.3 Gearboxes
1PH7/3-130
Siemens AG, 2004. All rights reserved
Induction Motors, 1PH7 (APH7S) – 05.04 Edition
3.3.8
Connections, circulating oil lubrication, frame size 100
M
K
E
G
L
D
F
Fig. 3-8
Selector gearbox with selector unit for frame size 100
Table 3-7
Connections for circulating oil lubrication
Max.
pressure
Connection,
oil return
Connection,
oil intake
Mounting position
0.2 bar
1.5 bar
D
M
(0.5 dm
3
/min)
K/L
(1.0 dm
3
/min)
V1
(closed version)
1.5 bar
D
Main direction of rotation,
1.5 bar
Main direction of rotation,
clockwise
1)
E
Main direction of rotation,
counter-clockwise
1)
G
(1.5 dm
3
/min)
main direction of rotation,
clockwise
F
(1.5 dm
3
/min)
main direction of rotation,
counter-clockwise
B5
V1
Note: Circulating oil lubrication is required for certain gearboxes and V1 or V3 vertical mounting posi-
tions (refer to Subsection 3.3.6)
1) When viewing the gearbox drive from the motor