67
Overvoltage category
According to IEC 61010 Part1
V
IN
to 480V (
ϕ
-
ϕ
)
Cat III
V
IN
to 600V (
ϕ
-
ϕ
)
Cat II
Power Supply
Cat II
Binary outputs, binary inputs
and relay outputs
Cat II
Analog inputs and analog
outputs
Cat III
Auxiliary power
Multi-range power supply unit
AC /DC
Nominal range
24 to 250 V DC or 100 / 230 V AC
Total range
7KG7610
only:
+/- 20% of nominal range
-10% ... +20% of nominal range DC
+/- 20% of nominal range AC
Power consumption
7KG7610
only:
max. 4 W or 10 VA
max. 10 W or 25 VA
Battery (only 7KG7200, 7KG7600, and 7KG7610)
Type
VARTA CR2032, 3 V, Li-Mn
(or similar)
Display
Graphic display
Resolution
120 x 240 pixels
Dimensions
103 x 60 mm
Dimensions, Weight
Panel mounted housing
(7KG7500/7KG7600/7KG7610)
Dimensions
144 x 144 mm
Weight
ca. 0,9 kg (without I/O modules)
ca. 0,95 kg (with 4 I/O modules and
connection
board)
Standard rail mounting
(7KG7100/7KG7200)
Dimensions
94 x 157 mm
Weight
ca. 0,55 kg