background image

Commissioning 

 

7.4 Notes on operation 

 

SIMATIC Rack PC 547B 

44

 

Operating Instructions, 12/2007, A5E01127519-02 

The table and information below apply only to the delivery state of the device, in other words, 

no changes or expansions have been made. 

 

 

 

 
 

RAID BIOS RAID software 

SATA interface 

Installation location 

Enclosure labeling 

Port 0 

Device Port 0 

SATA1 

(1) Removable 

cartridge 1  

1  

Port 2 

Device Port 2 

SATA3 

(2) Removable 

cartridge 2  

2  

Port 0 

Device Port 0 

SATA1 

(3) Side panel 1  

1  

Port 2 

Device Port 2 

SATA3 

(4) Side panel 2  

2  

Please replace the faulty drive with a new one of the same type and capacity. 

Summary of Contents for SIMATIC Rack PC 547B

Page 1: ...________ ______________ ______________ Introduction 1 Safety information 2 Description 3 Application planning 4 Mounting 5 Connecting 6 Commissioning 7 Integration 8 Functions 9 Expansions and configuration 10 Maintenance and service 11 Troubleshooting FAQs 12 Specifications 13 Dimension drawings 14 Detailed descriptions 15 Appendix A ESD directives B List of abbreviations acronyms C SIMATIC Indus...

Page 2: ...ntation Commissioning and operation of a device system may only be performed by qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Prescribed Usage Note the following WARNING This device m...

Page 3: ...Operator Controls 18 3 6 3 Connection components 19 3 6 4 Status indicators 21 4 Application planning 23 4 1 Transport 23 4 2 Unpacking and checking the delivery unit 23 4 3 Ambient and environmental conditions 25 4 4 Access protection 26 5 Mounting 27 5 1 Installing the device 27 6 Connecting 29 6 1 Connecting peripherals 29 6 2 Connecting the device to power 30 6 3 Equipotential bonding 33 7 Com...

Page 4: ...65 11 1 2 Replacing filters 66 11 1 3 Removing the device fan 67 11 1 4 Replacing the backup battery 69 11 1 5 Removing the power supply module 70 11 1 6 Removing the motherboard 71 11 1 7 Processor replacement 72 11 2 Reinstalling the software 74 11 2 1 General installation procedure 74 11 2 2 Restoring the Factory State of the Software Using the Restore DVD 75 11 2 3 Installing Windows 76 11 2 3...

Page 5: ...nsion drawings 99 14 1 Dimensional drawing of the device 99 14 2 Dimensional drawing for the use of telescopic rails 100 14 3 Dimensional drawings for the installation of expansion modules 101 15 Detailed descriptions 103 15 1 Motherboard 103 15 2 System resources 103 15 3 Interrupt assignments 104 15 4 BIOS Setup 107 A Appendix 109 A 1 Guidelines and declarations 109 A 2 Certificates and Approval...

Page 6: ...Table of contents SIMATIC Rack PC 547B 6 Operating Instructions 12 2007 A5E01127519 02 ...

Page 7: ...t fault error analyses Scope of validity of this document This documentation is valid for all variants of the SIMATIC Rack PC 547B and describes the device shipped as of December 2007 Position in the information landscape These operating instructions are available on the supplied Documentation and Drivers CD For supplementary instructions on how to handle the software please refer to the correspon...

Page 8: ...options and installation instructions Connecting Options of connecting the product and connection instructions Commissioning Commissioning the product system Integration Options of integrating the product into existing or planned system environments networks Functions Monitoring and display functions Expansions programming Installation of expansion devices memory modules drives Maintenance and ser...

Page 9: ...nvironment please contact your service representative Repairs Only authorized personnel are permitted to repair the device WARNING Unauthorized opening and improper repairs can cause considerable damage to property or danger for the user System expansions Only install system expansion devices designed for this device The installation of other expansions can damage the system and violate the radio ...

Page 10: ...body do not open do not short circuit do not reverse polarity do not heat above 100 C dispose of correctly and protect against direct sunlight dampness and dew ESD directives Modules containing electrostatic sensitive devices ESDs can be identified by the following label Strictly follow the guidelines mentioned below when handling modules which are sensitive to ESD Always discharge your body s sta...

Page 11: ...27519 02 11 Description 3 3 1 Overview The SIMATIC Rack PC 547B is a powerful industrial PC in 19 rack format design 4HE It is perfectly suited for high performance industrial PC applications Maximum performance Attractive price Figure 3 1 SIMATIC Rack PC 547B ...

Page 12: ...sidential and commercial areas and small businesses In addition to the industrial applications it can also be used in building services automation or in facilities open to the public 3 3 Highlights Highlights Latest PC technology State of the art Intel technology High performance and scalability PCI PCIe x1 PCIe x16 slots Industrial suitability Dust protection Service friendly CE certification for...

Page 13: ...sor Program execution watchdog RAID1 for automatic data mirroring of two serial ATA hard drives Enhanced diagnostic messaging by way of Ethernet E mail SMS and for direct input in SIMATIC software by way of OPC optional using SIMATIC PC DiagMonitor Operating hours counter Hard disk status System status Heart Beat Automatic logging of all messages to a log file Option of remote monitoring of networ...

Page 14: ... 25 and 1 x 3 5 Internal 2x 3 5 Slots for expansion cards 4 x PCI long 2 x PCIe x1 long 1 x PCIe x16 long Graphics Intel GMA950 on board graphics controller 2 D and 3 D engine integrated in chipset Dynamic Video Memory Technology uses up to 224 MB of RAM Max 1280x1024 at 100 Hz 32 bit color depth Max resolution 2048x1536 at 75 Hz 16 bit color depth in PCIe x16 slot optional PCIe x16 graphic card d...

Page 15: ...Hz 1066 MHz FSB 4 MB L2C EM64T VT RAM expansion 512 MB SDRAM DDR2 667 PC2 5300 Single channel 4 DIMM slots for maximum 4 GB Disk drives Floppy disk drive 1 44 MB 3 5 hard disk SATA 250 GB built in Operating system None Optional accessories Processor Intel Core 2 Duo E4300 1 8 GHz 800 MHz FSB 2 MB L2C EM64T Intel Celeron 440 2 0 GHz 800 MHz FSB 512 KB L2C RAM expansion Up to 4 GB dual channel Disk ...

Page 16: ... 2003 including 5Client MUI MUI Multi language User Interface 5 languages German English French Spanish Italian Languages that can be installed from recovery CD DVD Language Windows 2000 Windows XP Windows Server 2003 Windows Vista German X X X X English X X X X French X X X X Italian X X X X Spanish X X X X Japanese X X X Chinese Hong Kong X X Chinese simplified X X Chinese Taiwan X Korean X Opti...

Page 17: ...e drive cartridges 3 Installation options for DVD ROM drives DVD burners 4 On off button 5 Front door with lock provides protection against dirt and unauthorized access Keep the front door closed during normal operation 6 Diskette drive 7 USB ports 8 Rating plate 9 Status displays Rear view of the device Pos Description 1 Power unit fan 2 Fan aperture Installation option for 60 mm fan 3 Blanking p...

Page 18: ... on off reset buttons have three functions Switch on the PC press briefly 1x Shut down the operating system and PC press briefly 1x Switch off the PC without shutting down the operating system press and hold more than 4 seconds hardware reset CAUTION Data may be lost when the PC performs a hardware reset WARNING The on off button signal does not cut off power to the PC ...

Page 19: ...5 COM 2 Serial port 2 V 24 9 pin D sub connector optional 6 DMS59 connector DMS59 interface socket of the dual head graphics card optional 7 Micro input Microphone connection 8 Audio output Headphone connection 9 Audio input Connector for analog audio source Line in 10 USB A and B Connection for USB devices 11 VGA Connection for VGA monitor 12 COM 1 Serial port 1 V 24 9 pin D sub connector 13 KEYB...

Page 20: ...IC Rack PC 547B 20 Operating Instructions 12 2007 A5E01127519 02 Power supply Position of the IEC power connector Description IEC connector for the AC power supply to the device The maximum permitted power range is 120 to 240 V AC ...

Page 21: ...Description 1 STATUS Fan temperature status OFF RED No error Temperature critical CPU device temperature CPU heat sink fan fault Enclosure fan fault Power supply fan fault 2 HARDDISK Display for hard disk access OFF GREEN No access Access 3 POWER PC operating status display OFF YELLOW GREEN Hibernate switched off or unplugged Windows standby PC in operation ...

Page 22: ...Description 3 6 Design SIMATIC Rack PC 547B 22 Operating Instructions 12 2007 A5E01127519 02 ...

Page 23: ...ops on or inside the device If condensation develops wait at least 12 hours before switching on the device 4 2 Unpacking and checking the delivery unit Unpacking the device Note the following points when you unpack the unit It is advisable not to dispose of the original packing material Keep it in case you have to transport the unit again Please keep the documentation in a safe place It is require...

Page 24: ...the front door Figure 4 1 Rating plate Order number of the device Ethernet address The Ethernet address of the device is available in BIOS Setup F2 function key at Info F1 function key LAN Address Microsoft Windows Product Key on the Certificate of Authenticity COA The COA label is attached to the inside of the front door You may need the Product Key in case you reinstall the operating system Figu...

Page 25: ...xample locations with acidic vapors or gasses without additional protective measures such as the provision of clean air Keep the PC out of direct sunlight Mount the PC as safely as possible to prevent danger for example of falling over The device conforms to protection class IP 30 at the front panel The clearance in the area of the ventilation slots must be at least 50 mm so that the PC is suffici...

Page 26: ...ess protection The access protection of the Rack PC exists only when the front panel is closed and no keyboards with an On Off button power button are being used Note In Windows you have the option of setting the function of the On Off button to meet your requirements You can make these setting in the Power Options menu ...

Page 27: ...ng on device bases Tower installation a separate tower kit can be ordered for tower installation not available in some countries Mounting on telescopic rails These telescopic rails allow you to fully extract the device out of the cabinet or rack Refer to the sections Technical data of the telescopic rails and Dimensional drawing for the use of telescopic rails for more detailed information Positio...

Page 28: ...l metal base and secure it against tipping The following decide bases are available from Rittal for this purpose Rittal Type TE 7000 620 Rittal Type VR 3861 580 Rittal Type DK 7063 710 Please refer to the case manufacturer s instructions regarding device bases CAUTION Risk of injury It is not permitted to mount the device only on the 19 brackets of the front panel ...

Page 29: ...power supply CAUTION Strictly adhere to the specifications for peripheral equipment NOTICE The connected or added peripherals must not introduce any counter emf into the device A counter emf greater than 0 5 V to ground on the 3 3V DC 5V DC 12V DC power rail due to a connected or integrated component can prevent normal operation or even destroy the computer When measuring the counter emf remember ...

Page 30: ...mains voltage CAUTION The mains connector must be disconnected to fully isolate the device from mains Ensure easy access to this area A master mains disconnect switch must be installed if the device is mounted in a switch cabinet Always ensure free and easy access to the power inlet on the device or that the safety power outlet of the building installation is freely accessible and located close to...

Page 31: ...er cord must be used for the United States and Canada The connector must be compliant with NEMA 5 15 120 V AC power supply A flexible power cord approved to UL and with CSA label should be used It should have the following features Type SJT with three leads min 18 AWG conductor cross section max length 4 5 m parallel grounding plug 15 A min 125 V 240 V AC power supply A flexible power cord approve...

Page 32: ... in order to avoid unintentional disconnection of the power cord Steps for securing the power plug 1 Remove the fastening screw 1 on the power supply module 2 Screw the power plug interlock 2 onto the power supply module WARNING If the power plug is secured with a clamp the power outlet must be freely accessible to allow the device to be easily removed from the mains ...

Page 33: ...f interference generated by external power cables signal cables or cables for I O modules to ground Equipotential bonding terminal The equipotential bonding terminal 1 on the device large surface large area contact must be interconnected with the central grounding busbar of the cabinet or plant in which the PC is to be installed The minimum conductor cross section may not be less than 5 mm2 ...

Page 34: ...Connecting 6 3 Equipotential bonding SIMATIC Rack PC 547B 34 Operating Instructions 12 2007 A5E01127519 02 ...

Page 35: ...llows 1 Press the on off button The green power LED lights up The PC performs a POST During the self test this message appears Press F2 to enter SETUP 2 Wait until this message is cleared then follow the instructions on the screen 3 Type in the Product Key as required You find this key on the Certificate of Authentication in the Product Key line NOTICE The PC may not be switched off at any time du...

Page 36: ...ewall The Windows Firewall adds protection to the device by blocking network or Internet access to the device by unauthorized users Windows checks if the device is protected by a software firewall The firewall is enabled by default in the factory state Antivirus software Antivirus programs add protection to the device by searching for and eliminating viruses and other security threats Windows chec...

Page 37: ...drive run setup and follow the instructions on the screen NOTICE When first starting the burner software no disks should be inserted in the drive This is because disks with errors can interrupt the automatic hard drive recognition This makes it impossible to correctly display the possible burner functions Notes on burning optical disks CAUTION Danger of data errors when burning disks Burning is pe...

Page 38: ...drive 1 Check which hard disk the RAID controller has reported being faulty hard disk at channel 1 or 2 1 Power LED voltage supply available 2 HDD activity display The table below shows the assignment of the removable cartridge positions in the device to the RAID system reports RAID BIOS RAID software SATA interface Installation location Enclosure labeling Port 0 Device Port 0 SATA1 3 Removable ca...

Page 39: ...ATIC Rack PC 547B Operating Instructions 12 2007 A5E01127519 02 39 Notes on operation NOTICE Always interlock the hard disk cartridge with the removable cartridge in order to ensure reliable operation of the device 1 Removable cartridge lock ...

Page 40: ...information on hard disk capacities refer to your order documentation Booting from the slave hard disk In order to allow booting from the second hard disk you need to configure it as the primary boot device Make the following settings in your BIOS Setup Select Boot Hard Drive Disk name e g STxxxxxxxxx SATA3 then press the key to move it up in the boot order NOTICE The drive letters for the partiti...

Page 41: ...information regarding Intel RAID controllers in the RAID documentation on the included Documentation and Drivers CD in the Drivers RAID Intel directory Intel R Matrix Storage Manager option ROM v5 6 2 1002 ICH7R wRAID5 RAID Volumes ID Strip Size Bootable Level Status Copyright C 2003 06 Intel Corporation All Rights Reserved Name 0 N A 149 1GB Yes RAID1 Mirror Rebuild Volume0 Physical Disks Port Si...

Page 42: ...and returns details of the RAID volumes The command View System Report can be used to create a report with details of the RAID volumes NOTICE The RAID status entries are returned by default in the Windows event view and in the log file of the program A hard drive can be synchronized at operating system level if a fault is detected It may take up to several hours to synchronize a new disk in the ba...

Page 43: ...ation process In extreme cases input from the keyboard and touch screen may be delayed for a brief period Replacing a faulty drive in a RAID array Replace faulty RAID drives with a new drive in order to recover secure RAID1 state The RAID software reports the faulty drive and returns details of the operable hard drive The functioning hard drive is indicated in BIOS by its port number or by the RAI...

Page 44: ...words no changes or expansions have been made RAID BIOS RAID software SATA interface Installation location Enclosure labeling Port 0 Device Port 0 SATA1 1 Removable cartridge 1 1 Port 2 Device Port 2 SATA3 2 Removable cartridge 2 2 Port 0 Device Port 0 SATA1 3 Side panel 1 1 Port 2 Device Port 2 SATA3 4 Side panel 2 2 Please replace the faulty drive with a new one of the same type and capacity ...

Page 45: ...ot possible as BIOS level Points to note if the hard disk is replaced when the computer is turned off Only a hard disk that was active and functioning correctly when you booted can later be included in the RAID array To be able to boot from the RAID system you must place this first in the list of bootable sources in the BIOS Boot setup menu Otherwise the system will boot from the hard disk you hav...

Page 46: ...nstalling a functioning new hard disk unused will be displayed for the corresponding SATA port In this case you will need to shut down the system again and boot with the functioning hard disk The new hard disk is then assigned to a SATA port and can be included in the RAID array The Rebuild to this Hard drive command initiates synchronization of the RAID1 system ...

Page 47: ...tor should be deactivated Subsequently it can be reactivated Measures If the DiagMonitor Management Station is in operation on your device Close all applications also the Management Station Afterwards stop the DiagMonitor SNMP Agent SOL Agent In order to do so select Start Run and enter cmd in the field Afterwards enter Net stop snmp and confirm with the Enter key If your device is remotely monito...

Page 48: ...ioning 7 4 Notes on operation SIMATIC Rack PC 547B 48 Operating Instructions 12 2007 A5E01127519 02 NOTICE If you do not keep to the procedure described above a correct RAID configuration cannot be guaranteed ...

Page 49: ...m environments networks Ethernet The integrated Ethernet port 10 100 1000 Mbps can be used for communication and for data exchange with automation devices such as SIMATIC S7 For this purpose you require the SOFTNET S7 software package Additional information You can find additional information in the catalog and to the online ordering system of Siemens A D Internet address https mall ad siemens com...

Page 50: ...Integration 8 1 Integration SIMATIC Rack PC 547B 50 Operating Instructions 12 2007 A5E01127519 02 ...

Page 51: ...onitor Note The monitoring software is not preinstalled SystemGuard can be installed from the supplied Documentation and Drivers CD DiagMonitor can be ordered separately as an option and ships on CD NOTICE The SystemGuard and DiagMonitor software cannot be installed simultaneously Simultaneous installation and operation can result in errors because both programs access the same interfaces A descri...

Page 52: ...re error is retained until the temperatures have fallen below the thresholds and are reset by one of the following measures The error alarm is acknowledged by pressing the Info button on the SystemGuard user interface Restart of the device 9 3 Watchdog WD Function The watchdog monitors program execution and reports a program crash to the user by means of various reactions The watchdog can only be ...

Page 53: ...it is installed Additional information is available on the supplied Documentation and Drivers CD in Utilities Sysguard 9 5 Monitoring software The monitoring software is not installed SystemGuard can be installed from the supplied Documentation and Drivers CD This is located in the Utilities Sysguard directory DiagMonitor can be ordered as an option The DiagMonitor software CD contains the monitor...

Page 54: ...Functions 9 5 Monitoring software SIMATIC Rack PC 547B 54 Operating Instructions 12 2007 A5E01127519 02 ...

Page 55: ...e you open the device Refer to the ESD guidelines for handling electrostatic sensitive devices Tools All mechanical installation tasks on the device can be carried out with Torx T10 screwdrivers Preparation Disconnect the device from the mains Liability disclaimer All specifications and approvals apply only to expansion units which are released by SIEMENS No liability can be accepted for impairmen...

Page 56: ...n 10 1 Opening the device SIMATIC Rack PC 547B 56 Operating Instructions 12 2007 A5E01127519 02 Opening the device Steps for opening the enclosure cover 1 Remove the mounting screws 1 2 Lift up the lid from the back and remove it ...

Page 57: ...ions and configuration 10 1 Opening the device SIMATIC Rack PC 547B Operating Instructions 12 2007 A5E01127519 02 57 Steps for opening the device front 1 Tilt the front door 1 forward 2 Remove the fan cover 2 ...

Page 58: ...ensions If the height is exceeded you may experience contact problems malfunctions and difficulties with the assembly The permissible module dimensions are specified in the dimension drawings section NOTICE The performance is limited for PCI modules with 5V supply voltage The output of the modules may not exceed 25W in total Note about long PCI PCIe modules Before long modules can be inserted into...

Page 59: ... 2 Hold the posts 3 of the module bracket at both ends and lift it out 3 Remove the relevant steel slot cover 2 4 Insert the expansion module 1 into the relevant slot 5 Screw tighten the steel slot cover 2 of the expansion module 6 Insert the module bracket again 7 Release the free module bracket 4 fit it on the expansion module and secure it with the screws With short expansion modules you can re...

Page 60: ...talling disk drives The driver bay module consists of a horizontal and vertical driver carrier A DVD ROM DVD burner floppy drive or removable cartridge can be installed in the drive bay module Drive bay module Item Description 1 Horizontal drive bay 2 Vertical drive bay 3 3 5 floppy desk drive FD 4 5 25 mounting bays for DVD CD or hard drives in removable cartridges ...

Page 61: ... the device Removing the drive bay module The drive bay module consists of a horizontal and vertical drive bay Steps for removing the drive bay module 1 Loosen the mounting screws of the drive bay module 2 Disconnect the power cable and the data cable from the installed disk drives 3 Lift the drive bay module 1 out of the device until you can access the cables of the floppy disk drive Disconnect t...

Page 62: ...k drive in a horizontal drive bay 1 Slide the disk drive into the carrier from the front 2 Remove any vertical drive bay The only way to get at the mounting screws on the right side of the drive is through the openings of the vertical carrier 3 Mount the disk drive into the drive bay using four screws 4 Insert the drive bay module again 5 Connect the power and data cables to the disk drive ...

Page 63: ...evice from mains and disconnect all cables 2 Open the device Installing a drive How to install a drive 1 Connect the power and data cables to the disk drive 2 Hold the drive on the drive bay plate and secure it with 4 screws 1 or 2 Removing drives How to remove a drive 1 Disconnect the power and data cables from the drive 2 Remove the four screws 1 or 2 and take the drive out of the housing ...

Page 64: ...Expansions and configuration 10 4 Installing drives SIMATIC Rack PC 547B 64 Operating Instructions 12 2007 A5E01127519 02 ...

Page 65: ...pansion devices you may damage the system or violate the safety requirements and regulations on RF suppression Contact Technical Support or your local sales department to find out which system expansions are suitable for installation If you install or exchange system expansions and damage your device the warranty becomes void NOTICE Read the information about ESB Liability disclaimer All specifica...

Page 66: ...SIMATIC Rack PC 547B 66 Operating Instructions 12 2007 A5E01127519 02 11 1 2 Replacing filters Note Filter meshes are available under the following order numbers A5E00246975 How to replace the filter 1 Tilt the front door 1 downwards 2 Remove filter cover 2 and remove filter ...

Page 67: ...ructions 12 2007 A5E01127519 02 67 11 1 3 Removing the device fan Preparing for equipment fan exchange Unplug the device from mains Remove the fan Steps 1 Tilt the front door 1 downwards 2 Lift off the fan cover 2 3 Open the device cover 4 Unplug the fan connector from the motherboard 5 Remove all fan screws ...

Page 68: ...nd installing hardware components SIMATIC Rack PC 547B 68 Operating Instructions 12 2007 A5E01127519 02 Installing the fan NOTICE Always install a fan of the same type CAUTION Ensure that the arrow on the fan points away from the fan bracket ...

Page 69: ...parts for SIMATIC PCs is available at http www siemens com asis Disposal CAUTION Depleted batteries must be disposed of in accordance with local regulations Preparation Note The configuration data of the device are deleted when the battery is replaced Note the current BIOS Setup settings You can conveniently back up the BIOS settings by means of the SIMATIC PC BIOS manager Replacing the battery Th...

Page 70: ...ains and disconnect all cables 2 Open the device Removing the power supply unit How to remove the power supply module 1 Disconnect the power cables from the disk drives and motherboard 2 Remove the tie wraps holding the power cables in the housing 3 Remove the mounting screws TORX T10 1 4 Lift the power supply module out of the enclosure until you can access the power cable of the floppy disk driv...

Page 71: ...paration 1 Unplug the device from mains and disconnect all cables 2 Open the device Removing the motherboard How to remove the motherboard 1 Remove all modules from their slots 2 Disconnect all cables from the motherboard noting down their positions while doing so 3 Remove ten screws from the motherboard A replacement motherboard is supplied without processor and memory modules ...

Page 72: ...carried out by authorized qualified personnel If the processor type is changed the BIOS must be updated so that the suitable microcode is loaded Preparation 1 Unplug the device from mains 2 Open the device Removing the processor How to remove the processor 1 Unhook the fan holder on the heat sink and pull off towards the front 2 Disconnect the processor fan connector 3 Loosen the four screws and r...

Page 73: ...e processor Additional instructions can be found in the supplied Documentation Drivers CD in the D2156 S21 manual CAUTION Operating a processor at a frequency higher than it specified speed can result in damage to the device and the loss of data Only certified and approved processors can be used with the supplied motherboard For more information contact your local Siemens representative http www s...

Page 74: ...CD DVD contains the Windows user interface with tools for configuring the hard drives and for installation of the operating system and the languages supported by the operating system MUI The basic language of the operating system that is installed is English If you want to include additional languages you can install these later from the recovery CD2 or DVD Documentation and Drivers CD Contains th...

Page 75: ...e you can obtain information necessary for software authorization CAUTION If Restore system partition only is set all data on drive C system partition will be deleted All data user settings and all authorizations or license keys on drive C are lost All data on drive C of the hard disk will be deleted Setup formats the hard disk and installs the original factory software If Restore entire hard disk...

Page 76: ...During the rest of the installation you will be asked several times for the missing driver of the controller Booting from recovery CD or DVD 1 To boot from the recovery CD or DVD press the F12 key during the self test phase The boot menu displayed after initialization indicates all boot devices 2 Select the CD DVD drive Follow the instructions on the screen until the Siemens SIMATIC Recovery windo...

Page 77: ...d Second Windows 2000 XP Server 2003 DATA Remainder NTFS not compressed 1 Boot from the Recovery CD and then follow the on screen instructions until the Recovery functions window is displayed 2 Start the DiskPart tool in the Siemens SIMATIC Recovery window Enter the following commands in the displayed command interface List disk Displays all available hard disks Select disk 0 Selects the disk wher...

Page 78: ...CD to format the partitions Follow the screen instructions until the Recovery functions window is displayed 2 Select Start command prompt in the Recovery functions window Enter the following command in the displayed command prompt format drive FS file system drive drive letter of the partition to be formatted Valid values C D E F etc File system Specifies the type of file system Valid values FAT F...

Page 79: ...mand in the displayed command prompt interface Drive cd I386 Winnt32 bat Drive Drive letter of the folder containing the I386 directory 6 The preparation of the Windows installation is displayed 7 When this is completed close the command prompt with the exit command 8 Close the Siemens SIMATIC Recovery window with the Finish button 9 The Windows installation is completed following an automatic res...

Page 80: ...on for Windows 2000 MUI Setting up the language selection for Windows 2000 MUI The Multilanguage User Interface MUI of Windows 2000 allows you to change the menu and dialog language The dialog language for Windows 2000 menus and for the keyboard layout are set in the corresponding Control Panel dialog Start Settings Control Panel Regional Options General tab Setting for the current user field and ...

Page 81: ... language setting of your Windows installation is English with US keyboard layout You can change the language in the Control Panel Start Control Panel Date Time Language and Regional Options Add other languages Languages tab Language used in menus and dialogs field For the Date Time Language and Regional Options set the default as non Unicode programs under Advanced in addition to the language for...

Page 82: ...he MUI The MUI is on the recovery DVD Now follow the on screen instructions It may take several minutes before the next prompt for the product key is displayed Note Due to the previous activation you do not need to enter the product key COA number This is entered automatically during the installation Setting up and formatting partitions After you have installed a new hard disk or if partitions are...

Page 83: ...lete Deleting a partition Format Formatting a partition New Creating new partitions Load Driver To add new drivers for example the driver for RAID Extend Changing the partition size Any error messages that occur are displayed behind this icon for example if the hard disk was not formatted in the required NTFS format The first partition should be at least 25 GB The operating system must be installe...

Page 84: ...pecific information for administrators who install manage and integrate Windows in networks or multi user environments Setting up language options in Windows Vista With the Multilanguage User Interface MUI you can set up the Windows menus and dialogs for additional languages When shipped Windows Vista is installed with English menus and dialogs You can change this in the Control Panel with the Reg...

Page 85: ...he required driver NOTICE If you require the driver for the chipset after reinstalling Windows 2000 XP Server 2003 Vista this must always be installed first before all other drivers 11 2 8 Installing the RAID Controller software The procedure for installing the software can be found in the user manual on the supplied Documentation and Drivers CD in the directory Drivers RAID Intel Note on Windows ...

Page 86: ...responding manufacturer 11 2 10 2 Installing or updating application programs and drivers Install and connect an appropriate drive in order to install software from a CD and or floppy disk in Windows The USB floppy disk and CD ROM drivers are included in Windows and do not have to be installed from other sources For information about installation of SIMATIC software packages refer to the correspon...

Page 87: ...using SIMATIC PC Image Creator to generate backup copies of your data This tool provides comfortable and efficient functions for backup and restoring the full content of Compact Flash cards of HDDs and of individual partitions images The software can be ordered from the Siemens A D online ordering system For detailed information about SIMATIC PC Image Creator please refer to the corresponding prod...

Page 88: ...Maintenance and service 11 2 Reinstalling the software SIMATIC Rack PC 547B 88 Operating Instructions 12 2007 A5E01127519 02 ...

Page 89: ...ble has been properly connected to the system unit and to the monitor The external monitor remains dark The power cord or the monitor cable is not connected If the monitor screen still remains dark after you have performed these checks please contact your technical support team The mouse driver is not loaded Check whether the mouse driver is properly installed and present when you start the applic...

Page 90: ...use the drive is not installed The Serial ATA plug in failed to load because the driver is not installed correctly The Intel Matrix Storage Console was unable to load a page for the following reason A plug in did not provide a page for the selected device A plug in failed to load RAID is not activated RAID is activated The messages have no negative effect on the operation of the device and can be ...

Page 91: ...ult Replace this module with a Siemens module or contact the module supplier Force a Reset Configuration using the BIOS Setup The PC crashes during startup Double allocation of I O addresses Double allocation of hardware interrupts and or DMA channels Signal frequencies or signal levels are incorrect Connector assignments deviate No Reset Configuration executed in BIOS SETUP Contact Technical Supp...

Page 92: ...Troubleshooting FAQs 12 2 Problems when using modules of third party manufacturers SIMATIC Rack PC 547B 92 Operating Instructions 12 2007 A5E01127519 02 ...

Page 93: ...ax 63 Hz sinusoidal Transient voltage interruption 16 ms at 0 85 UN max 10 events per min recovery time 1s Power consumption with 210 W secondary 310 W approx 68 efficiency Max current output AC 3 3 V 24 A 5V 26A max 190 W total allowed 12V 15 12V 15 12V 0 2A 5Vaux 2A Noise emission 45 dB A to DIN 45635 Degree of protection IP 30 with closed front door IP 20 at the back in conformity to EN 60529 D...

Page 94: ...mperature Tested to IEC 60068 2 2 IEC 60068 2 1 IEC 60068 2 14 In operation Gradient Storage transport Gradient 5 to 40 C without burner operation 5 to 35 C with restriction CPU up to 65W power loss See Retrofitting instructions max 10 C h no condensation 20 to 60 C max 20 C h no condensation Relative humidity Tested to IEC 60068 2 78 IEC 60068 2 30 In operation Gradient Storage transport Gradient...

Page 95: ...Vaux 0 4A PCIe x16 module 3 3V 3A 12V 2 1A 3 3Vaux 0 4A 5V 5A or 3 3V 7A 12V 0 5 A 12V 0 05 A 3 3 Vaux 0 4A Accumulated power loss all voltages may not exceed 25 W The total consumption of all modules may not exceed 25W Total power consumption of 80 W must not be exceeded In total the 3 3 Vaux current of 1 2 A must not be exceeded Drives for configuration details refer to the order documentation F...

Page 96: ...arallel port printer VGA internal As an alternative PCIe x16 dual head Connection of an analog monitor Connection of two digital or analog monitors Keyboard PS 2 keyboard connection Mouse PS 2 mouse connection USB 6 channels 4 at back 2 in front high current high speed USB 2 0 Ethernet Broadcom BCM 5751 Ethernet interface RJ45 10 100 1000 Mbps Audio Mic in Line in Line out Realtek ALC262 Audio Cod...

Page 97: ...rd disk drive SATA 0 5 A 0 7 A DVD ROM 0 9 A 0 8 A DVD burner 1 1 A 1 4 A Single lines of current max permissible 1 26 A 24 A 30 A 0 2 A 2 A Total power consumption permissible 200 W Efficiency of the power supply Approx 68 230 V AC approx 65 115 V AC 1 The max permitted accumulated power of the 5 V and 3 3 V is 190 W 13 3 AC voltage supply Output voltage Voltage Max current Voltage stability 12 V...

Page 98: ...ions 12 2007 A5E01127519 02 13 4 Technical data of the telescopic rails Ultimate load per pair At least 30 kg Full extraction length At least 470 mm Rail thickness Maximum 9 7 mm Mounting screws M5 x 6 mm The mounting screws of the telescopic rails may not protrude by more than 5 mm into the enclosure ...

Page 99: ...g Instructions 12 2007 A5E01127519 02 99 Dimension drawings 14 14 1 Dimensional drawing of the device 7RS LQ YHUWLFDO PRXQWLQJ SRVLWLRQ 7RS LQ YHUWLFDO PRXQWLQJ SRVLWLRQ LPHQVLRQV PP QFK Figure 14 1 Dimension drawing of the device ...

Page 100: ...ensional drawing for the use of telescopic rails LPHQVLRQV PP QFK 7 7ROHUDQFH s PP QFK 7 7ROHUDQFH s PP QFK 7 7ROHUDQFH s PP QFK LPHQVLRQV IRU WHOHVFRSLF UDLOV E WKH FRPSDQ 6FKURII W SH LPHQVLRQV IRU WHOHVFRSLF UDLOV E WKH FRPSDQ 5LWWDO W SH s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 Figure 14 2Dimension drawing for the use of telescopic rails ...

Page 101: ...nal drawings for the installation of expansion modules SIMATIC Rack PC 547B Operating Instructions 12 2007 A5E01127519 02 101 14 3 Dimensional drawings for the installation of expansion modules Figure 14 3 Long PCI module PCIe module ...

Page 102: ...Dimension drawings 14 3 Dimensional drawings for the installation of expansion modules SIMATIC Rack PC 547B 102 Operating Instructions 12 2007 A5E01127519 02 ...

Page 103: ...6 S motherboard on the supplied Documentation and Drivers CD 15 2 System resources All system resources hardware addresses memory configuration allocation of interrupts DMA channels are assigned dynamically by the Windows OS depending on the hardware configuration drivers and connected external devices You can view the current configuration of system resources or possible conflicts with the follow...

Page 104: ...OLQH XQFWLRQV 54 3 PRGH 54 3 PRGH QWHUUXSW LQ 3 DQG 3 PRGH QWHUUXSW LQ 3 PRGH BIOS default interrupt in PIC mode e g DOS RPPHQWV 86 SRUW RVW 3 54 OLQH WR LV DVVLJQHG WR 54 WR LQ 3 PRGH RVW 3 54 OLQH WR LV DXWRPDWLFDOO DVVLJQHG WR 54 WR LQ 3 PRGH 26 VHWXS PRGH DXWR D PDQXDO DVVLJQPHQW WR D SDUWLFXODU 54 FDQ DOVR EH IRUFHG LQ WKH 26 VHWXS 26 VHWXS GYDQFHG 3 RQILJXUDWLRQ 3 54 LQH WR 54 L HG L HG L HG...

Page 105: ... mode e g DOS RPPHQWV 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 6ORW 3 6ORW 3 H 6ORW 3 H 6ORW 3 6ORW 3 6ORW 3 6ORW 3 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH 3 54 OLQH RVW 3 54 OLQH WR LV DVVLJQHG WR 54 WR LQ 3 PRGH RVW 3 54 OLQH WR LV DVVLJQHG WR 54 WR DXWRPDWLFDOO LQ 3 PRGH 26 VHWXS PRGH DXWR LW LV DOVR SRVVLEOH WR IRUF...

Page 106: ...ble Assigning an exclusive interrupt in BIOS Setup PIC mode only The interrupts are automatically assigned to the slots at system startup due to the default settings in system BIOS Depending on the system configuration it is possible that the same interrupt is assigned to several slots This functionality is known as interrupt sharing There is no exclusive interrupt available in PIC mode Disable sp...

Page 107: ...All RAID optional for RAID systems Disabled Advanced Advanced System Configuration Core Multi Processing Disabled on Windows 2000 systems System Mode Config Performance APM Interface Disabled APM Power saving Disabled ACPI Save to RAM Disabled Power Power failure recovery Always on The BIOS reference manual on the supplied Documentation Drivers CD shows you how to access and change the BIOS setup ...

Page 108: ...Detailed descriptions 15 4 BIOS Setup SIMATIC Rack PC 547B 108 Operating Instructions 12 2007 A5E01127519 02 ...

Page 109: ...and small businesses EN 61000 6 3 2001 EN 61000 6 1 2001 The devices conform with EN 61000 3 2 2000 harmonics and EN 61000 3 3 1995 A1 2001 voltage fluctuations and flicker Low voltage guideline The devices complies with the requirements of the EC Directive 2006 95 EC Low Voltage Directive Conformance with this standard has been verified according to EN 60950 1 Conformity certificates The EC decla...

Page 110: ... The following approval is available for the device Underwriters Laboratories UL to Standard UL 60950 1 Report E11 5352 and Canadian National Standard CAN CSA C22 2 No 60950 1 I T E EMC USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules Thes...

Page 111: ...ith Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CANADA Canadian notice This Class A digital apparatus complies with Canadian ICES 003 Avis Canadian Cet appareil numérique de la classe B est conforme à la...

Page 112: ... www siemens com sitrain Find a contact at Phone 49 911 895 3200 Technical support Tel 49 180 5050 222 Fax 49 180 5050 223 http www siemens com automation service You will find support request web form at http www siemens de automation support request When you contact the customer support please have the following information for the technician on hand BIOS version Order No MLFB of the device Inst...

Page 113: ...EOH FDUWULGJH ORSS Figure A 1 For the temperature range 5 to 35 C A removable cartridge with hard disk can be installed instead of DVD drive s Devices equipped with removable cartridges may not to be exposed to shock during operation as described by DIN IEC 600682 Approved configuration versions for the temperature range 5 to 40 C ORSS 9 520 9 520 RU LQ WKH UHPRYDEOH FDUWULGJH 9 520 RU LQ WKH UHPR...

Page 114: ...Appendix A 4 Retrofitting instructions SIMATIC Rack PC 547B 114 Operating Instructions 12 2007 A5E01127519 02 ...

Page 115: ...es are commonly referred to as ESD devices This is also the international abbreviation for such devices ESD modules are identified by the following symbol CAUTION ESD devices can be destroyed by voltages well below the threshold of human perception These static voltages develop when you touch a component or electrical connection of a device without having drained the static charges present on your...

Page 116: ...XPLGLW LQ N9 Figure B 1 Electrostatic voltages on an operator Basic protective measures against electrostatic discharge Ensure good equipotential bonding When handling electrostatic sensitive devices ensure that your body the workplace and packaging are grounded This prevents electrostatic charge Avoid direct contact As a general rule only touch electrostatic sensitive devices when this is unavoid...

Page 117: ...cing power consumption of the PC AS Automation system ASIS After Sales Information System AT Advanced Technology ATA Advanced Technology Attachment ATX AT Bus Extended AWG American Wire Gauge US standard for the cable diameter BIOS Basic Input Output System Basic Input Output System CAN Controller Area Network CD ROM Compact Disc Read Only Memory Removable storage medium for large data volumes CD ...

Page 118: ...eady for operation DTR Data Terminal Ready Data terminal is ready DVD Digital Versatile Disk Digital versatile disk DVI Digital Visual Interface Digital display interface DVI I Digital Visual Interface Digital display interface with digital and VGA signals ECC Error Correction Code Error correction code ECP Extended capability port Extended parallel port EGA Enhanced Graphics Adapter PC to monitor...

Page 119: ...dule IRQ Interrupt Request Interrupt request ISA Industry Standard Architecture Bus for expansion modules ITE Information Technology Equipment L2C Level 2 cache LAN Local Area Network Computer network that is limited to a local area LCD Liquid Crystal Display Liquid crystal display LEDs Light Emitting Diode Light emitting diode LPT Line Printer Printer port LVDS Low Voltage Differential Signaling ...

Page 120: ...ociation PI Protective Earth Protective conductor PEG PCI Express Graphics PG Programming device PIC Programmable Interrupt Controller Programmable interrupt controller POST Power On Self Test PXE Preboot Execution Environment Software for running new PCs without hard disk data via the network RAID Redundant Array of Independent Disks Redundant hard disk array RAM Random Access Memory RI Ring Inpu...

Page 121: ...inational standards with CSA Canada standards UMA Unified Memory Architecture Video memory URL Uniform Resource Locator Designation of the full address of an Internet page USB Universal Serial Bus UXGA Ultra Extended Graphics Array Graphic standard maximum resolution 1600x1200 pixels V 24 ITU T standardized recommendation for data transfer via serial ports VDE Verein deutscher Elektrotechniker Uni...

Page 122: ...List of abbreviations acronyms C 1 Abbreviations SIMATIC Rack PC 547B 122 Operating Instructions 12 2007 A5E01127519 02 ...

Page 123: ... generate backup copies of data files and manage both the current and the previous versions on the hard disk Baud Physical unit for the step speed in signal transmission Defines the number of transferred signal states per second With only two states one baud is equivalent to a transmission rate of 1 bps BEEP code If the BIOS detects a boot error it outputs an audible warning based on the current t...

Page 124: ...medium in card format and without moving parts The CF card contains the non volatile memory and the controller The interface of the CF card corresponds with the IDE interface CF cards can be operated without additional electronics on PCMCIA or IDE hard disk controllers using a plug and socket adapter There are two design forms CF I 42 6 x 36 4 x 3 3 mm and CF II 42 8 x 36 4 x 5 mm Configuration fi...

Page 125: ...ificantly increase the speed of computing and program execution compared to the previous generation of single core processors with hyperthreading technology EMC directive Directive concerning Electromagnetic Compatibility Compliance is confirmed by the CE symbol and the EC certificate of conformity Energy management The energy management functions of a modern PC allow individual control over the c...

Page 126: ...drives hard disks with integrated magnetic disks Hot swapping The SATA interface gives the device s hard drive system hot swap capability Prerequisite for this configuration is a RAID1 system with SATA RAID controller on board or slot module and at least two SATA removable cartridges The advantage of hot swapping is that defective hard disks can be replaced without having to reboot the computer Hu...

Page 127: ...ists of a group of computers and other devices that are distributed across a relatively restricted range and are linked with communication cables The devices connected to a LAN are called nodes The purpose of networks is the mutual use of files printers or other resources Legacy USB support Support of USB devices e g mouse keyboard on the USB ports without driver License key The license key repres...

Page 128: ...is sufficient for them Motherboard The motherboard is the core of the computer Here data are processed and stored and interfaces and device I Os are controlled and managed NEC Class 2 The NEC National Electrical Code is the USA collection of regulations that generally correspond to German VDE 0100 standards All USA standards governing the safety of electrical equipment and corresponding deviations...

Page 129: ...rface cards Type III cards are equipped with devices that require more space for example wireless communication modules or rotary storage media such as hard disk drives for example PC 104 PC 104 Plus Two bus architectures are especially fashionable today in the industrial world PC 104 and PC 104 Plus Both are standard in single board computers of the PC class The electrical and logical layout of t...

Page 130: ...can involve operating system installations or servicing tools for example RAID Redundant Array of Independent Disks Data storage system which is used to save data and the corresponding error correction codes parity bits for example to at least two hard disk volumes in order to enhance reliability and performance The hard disk array is controlled by management programs and a hard disk controller fo...

Page 131: ...ion that is the configuration of the hardware on the PC PG is defined The device configuration of the PC PG is preset with defaults Changes must therefore be entered in the SETUP if a memory expansion new modules or a new drive are added to the hardware configuration STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers Track at once In track at once recording a ...

Page 132: ...des a standard graphical interface based on drop down menus windowed regions on the screen and allows operation with a pointer device such as a mouse WLAN Wireless LAN is a local network that transmits data via radio waves infrared light or another wireless technology Wireless LAN is mainly used for mobile computer applications in office or factory environments ...

Page 133: ...ts 19 D Data backup 87 Degree of protection 93 Device configuration 107 Device fan 67 Disk drives 15 Drive bay module 60 Drive bay plate 63 Dust protection 93 DVD burner 15 37 DVD player 37 DVD ROM Installing burner or DVD software 85 Operating notes 37 E Electrostatic sensitive devices 10 EMC 110 Enclosure suppliers 28 Equipotential bonding 33 Error messages 89 ESD directives 10 ESD guidelines 11...

Page 134: ...of functions 15 Status displays 21 Watchdog 15 52 Monitoring software 53 Motherboard 103 Motherboard Configuration 71 Mounting Modules 59 Mounting locations 27 Mounting methods 27 Mounting holes 27 Multilanguage User Interface 80 O Online ordering system 49 Open Opening the device 56 Open the front door 56 Opening the device 56 Operating system 14 35 79 Initial commissioning 35 Updates 86 Windows ...

Page 135: ...bay module 61 Repairs 9 65 Replacing a hard disk 38 Replacing filters 66 Restart 35 Restore DVD 75 Retrofitting instructions 113 S Safety instructions 9 Serial number 24 Shipping 23 Simatic S7 49 Slot cover 59 Slots 14 SOFTNET S7 49 Specifications 93 Status displays 21 96 Supply voltage 31 93 System partition 75 System resources 103 T Telescopic rails 98 Temperature monitoring 52 53 Temperature ra...

Page 136: ...Index SIMATIC Rack PC 547B 136 Operating Instructions 12 2007 A5E01127519 02 ...

Reviews: