Detailed descriptions
16.6 Communication processor CP 1616 onboard
SIMATIC Rack PC 847B
Operating Instructions, 06/2008, A5E02203168-01
199
NOTICE
When loading the firmware or commissioning the module, be aware that the CP 1616
onboard takes five MAC addresses (always in direct sequence). The first two are shown in
the BIOS.
Example
The lowest address is for the layer 2 communication. The second is for Ethernet/PROFINET
communication.