Notes on RAID configuration with installed SIMATIC PC DiagMonitor software
When creating a RAID-system where SIMATIC PC DiagMonitor software is being used, the
Intel Matrix Storage Console may abort the process with the following error message:
Solution:
Before performing a RAID commissioning, the SIMATIC PC DiagMonitor should be
deactivated. Subsequently, it can be reactivated.
Measures:
If the DiagMonitor Management Station is in operation on your device:
●
Close all applications, including the Management Station.
●
Afterwards, stop the DiagMonitor SNMP Agent (SOL Agent). In order to do so, select
Start > Run and enter
cmd
in the Open field.
●
Then enter
Net stop snmp
and confirm with the Enter key.
If your device is remotely monitored with SIMATIC PC DiagMonitor:
In this case you need only stop the DiagMonitor SNMP Agent (SOL Agent).
●
In order to do so, select Start > Run and enter
cmd
in the Open field.
●
Then enter
Net stop snmp
and confirm with the Enter key.