Device Management
3.2 Configuring the Device
The serial console port implements RS232 DCE (Data Communication Equipment) on
a DB9 connector. The following is the pin-out for the port:
1
5
9
6
Figure 3.1
Serial DB9 Console Port
Pin
Name
Description
Reserved (Do Not Connect)
2
TX
Transmit Data
3
RX
Receive Data
Reserved (Do Not Connect)
5
GND
Signal Ground
6
Reserved (Do Not Connect)
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
9
Reserved (Do Not Connect)
Connected internally.
Connected internally.
Ethernet Ports
Connect any of the available Ethernet ports on the device to a management switch
and access the RUGGEDCOM RS930W console and Web interfaces via the device's
IP address. The factory default IP address for the RUGGEDCOM RS930W is
For more information about available ports, refer to
3.2
Configuring the Device
Once the device is installed and connected to the network, it must be configured. All
configuration management is done via the RUGGEDCOM RS930W interface. For more
information about configuring the device, refer to the
RUGGEDCOM RS930W User
Guide
associated with the installed software release.