Certification
6.2 EMC and Environmental Type Tests
Test
Description
Test Levels
Severi-
ty Levels
AC Pow-
er Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports
10 V
3
DC Pow-
er Ports
10 V
3
AC Pow-
er Ports
10 V
3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
IEC
61000-4-8
Magnetic Field
Enclo-
sure Ports
40 A/m Continuous
1000 A/m for 1 s
IEC
61000-4-11
Voltage Dips and Interrupts
AC Pow-
er Ports
100% for 5 Periods
100% for 50 Periods
Signal Ports
2.5 kV Common
Mode @ 1 MHz
1 kV Differential
Mode @ 1 MHz
3
DC Pow-
er Ports
2.5 kV Common
Mode @ 1 MHz
1 kV Differential
Mode @ 1 MHz
3
IEC
61000-4-12
Damped Oscillatory
AC Pow-
er Ports
2.5 kV Common
Mode @ 1 MHz
1 kV Differential
Mode @ 1 MHz
3
Signal Ports
30 V Continuous
300 V for 1 s
4
IEC
61000-4-16
Mains Frequency Voltage
DC Pow-
er Ports
30 V Continuous
300 V for 1 s
4
IEC
61000-4-17
Ripple on DC Power Supply
DC Pow-
er Ports
10%
3
IEC
61000-4-29
Voltage Dips and Interrupts
DC Pow-
er Ports
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
Signal Ports 2 kV (Failsafe Relay Output)
DC Pow-
er Ports
1.5 kV
Dielectric Strength
AC Pow-
er Ports
2 kV
Signal Ports 5 kV (Failsafe Relay Output)
DC Pow-
er Ports
5 kV
IEC 60255-5
HV Impulse
AC Pow-
er Ports
5 kV
40
RUGGEDCOM RS930W
Installation Manual, 02/2020, C79000-G8976-1035-07