Certification
6.2 EMC and Environmental Type Tests
Description
Test Levels
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
±4 kV at 2.5 kHz
DC Power Ports
±4 kV
AC Power Ports
±4 kV
Fast Transient
Earth Ground Ports
±4 kV
Signal Ports
2.5 kV Common Mode at 1 MHz
DC Power Ports
1 kV Common and Differential Mode at 1 MHz
Oscillatory
AC Power Ports
1 kV Common and Differential Mode at 1 MHz
Signal Ports
2 kVAC
DC Power Ports
1.5 kVDC
Dielectric Strength
AC Power Ports
2 kVAC
Signal Ports
5 kV (Failsafe Relay)
DC Power Ports
5 kV
HV Impulse
AC Power Ports
5 kV
Environmental Type Tests
Test
Description
Test Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
IEC 60255-21-1
Vibration
2 g at 10-150 Hz
IEC 60255-21-2
Shock
30 g at 11 ms
RUGGEDCOM RS400F
Installation Manual, 02/2020, C79000-G8976-1341-04