Installing the Device
2.3.1 Mounting the Device on a DIN Rail
Forced airflow is not required. However, any increase in airflow will result in a reduc-
tion of ambient temperature and improve the long-term reliability of all equipment
mounted in the rack space.
Note
For detailed dimensions of the device with either rack, DIN rail or panel hardware in-
stalled, refer to
"Dimension Drawings (Page 29)"
.
2.3.1
Mounting the Device on a DIN Rail
The RUGGEDCOM RS400F can be ordered with panel/DIN rail adapters preinstalled on
each side of the chassis. Use the adapters to mount the device to a standard 35 mm
(1.4 in) IEC/EN 60715 or TS35 DIN rail.
Mounting the Device
To mount the device to a DIN rail, do the following:
1. Hook the top teeth of the adapters onto the DIN rail.
2
2
2
3
1
1
1
Panel/DIN Rail Adapter
2
DIN Rail
3
Screw
Figure 2.1
Mounting the Device to a DIN Rail
2. Install one of the supplied #8-32 lock screws on either side of the device to se-
cure the adapters to the DIN rails.
RUGGEDCOM RS400F
Installation Manual, 02/2020, C79000-G8976-1341-04
9