Installing and connecting the device
3.3 Connecting the device
SIMATIC IPC347G
34
Operating Instructions, 10/2020, A5E50059993-AA
3.3
Connecting the device
3.3.1
Country-specific information on supply voltage
Country-specific information
The power supply cable must conform to the safety regulations of the country in which the
devices are installed and bear the marks required in each case.
This device must be equipped with a safety-tested power cord which may only be connected
to a grounded shockproof power outlet. Use a flexible cable with the following features:
230 V supply voltage of the USA and Canada
•
Type SJT with three conductors
•
The connector must be compliant with NEMA 5-15.
•
Conductor cross-section
≤
18 AWG
•
Cable length
≤
4.5 m
120 V supply voltage of the USA and Canada
•
Type SJT with three conductors
•
The connector must be compliant with NEMA 5-15.
•
Conductor cross-section
≤
18 AWG
•
Cable length
≤
4.5 m
240 V supply voltage
•
Type SJT with three conductors
•
Conductor cross-section
≤
18 AWG
•
Cable length
≤
4.5 m
100 V supply voltage
•
Type SJT with three conductors
•
Conductor cross-section
≤
18 AWG
•
Cable length
≤
4.5 m
220V supply voltage
•
Type RVV with three conductors
•
conductor cross-section
≤
18 AWG
•
Cable length
≤
4.5 m