Commissioning the device and device functions
4.3 Advanced device functions
SIMATIC IPC227G
Operating Instructions, 06/2021, A5E50059933-AA
37
4.3
Advanced device functions
4.3.1
Monitoring functions
4.3.1.1
Overview of the monitoring functions
The device also provides monitoring functions. The following display, monitoring and control
functions are available when the appropriate software is used:
•
Temperature monitoring (overtemperature or low temperature)
•
Monitoring of SSD with S.M.A.R.T. functionality
•
Watchdog (hardware or software reset of the computer)
•
Operating hours meter (information on total runtime)
SIMATIC IPC DiagBase software
Use the functions of the SIMATIC IPC DiagBase software for local monitoring. Use the
"DiagBase Management Explorer" application to obtain a clear overview of the controls. Use
the DiagBase Alarm Manager to receive notifications about individual alarms.
Note
For more information on SIMATIC IPC DiagBase software functionality, refer to the SIMATIC
IPC DiagBase Operating Manual
https://support.industry.siemens.com/cs/ww/en/view/109749690
).
4.3.1.2
Temperature monitoring/display
Temperature monitoring
Three temperature sensors monitor the temperature of the device at several positions:
•
Processor temperature
•
Temperature nearby the RAM module
•
Temperature nearby the CPU
A temperature error is triggered when one of the three temperature values exceeds the set
temperature threshold and the following reaction is initiated:
Reaction
Option
The DiagBase or DiagMonitor software is enabled
None