SIMATIC IFP2200/2400 ITC2200/2400 frameless
32
A5E48015893-AC, 03/2021
Information on insulation tests, protection class and degree of protection
Insulation test
The insulation strength is demonstrated in the type test with the following test voltages in accordance with IEC 61010-2-201:
Circuit
Insulation tested with (type test)
Rated voltage U
e
24 V
707 V DC to other circuits or to ground
Degree of pollution and overvoltage category
The device meets the following requirements according to IEC 61010-2-201:
Degree of pollution
2
Overvoltage category
II
Protection class
Protection class III according to IEC 61010-2-201.
Protection against foreign objects and water
The device meets the requirements according to IEC 60529.
Device side
Degree of protection
Front
• IP65: Only bonding between glass and mounting frame
• IP20 (Enclosure Type 1, indoor use only)
Rear panel
• IP00: No protection against contact with standard probes. No protection
against the ingress of water, dust and noxious gas.
To achieve higher protection classes, the device must be installed with the appropriate seal.
Technical Support
Technical support for the products covered in the manual is available in the Internet at:
• Technical support (
https://support.industry.siemens.com/cs/ww/en/
• Support Request (
https://support.industry.siemens.com/cs/ww/en/ps
• After Sales Information System SIMATIC IPC/PG (
https://support.industry.siemens.com/cs/ww/en/view/109782922
• Service (
https://support.industry.siemens.com/cs/ww/en/sc
• Contact persons and office locations (
https://www.automation.siemens.com/aspa_app?lang=en
• Training (
Additional information on SIMATIC products is available in the Internet at:
• Industry Mall (
https://mall.industry.siemens.com/goos/WelcomePage.aspx?regionUrl=/US&language=en
• Documentation Collection (
https://support.industry.siemens.com/cs/ww/en/
SIMATIC IFP2200/2400 ITC2200/2400 frameless
A5E48015893-AC, 03/2021
Siemens AG
Digital Industries
Postfach 48 48
90026 NÜRNBERG
GERMANY