Observe the information on chemical resistance on the Internet "Chemical resistance of the HMI devices and industrial PCs
https://support.industry.siemens.com/cs/ww/en/view/39718396
)".
Procedure
1.
Switch off the device.
2.
Dampen the cleaning cloth.
3.
Spray the cleaning agent on the cloth and not directly on the device.
4.
Clean the device with the cleaning cloth.
Cleaning the transceiver unit
Clean the enclosure surface with a damp cloth and make sure that no water enters the device.
Technical specifications
Technical specifications
Device
IFP2200 frameless ITC2200 frameless IFP2400 frameless ITC2400 frameless
Mechanical data
(without packing)
Width
522 mm
578 mm
Height
324 mm
356 mm
Depth
69.3 mm
79.5 mm
70 mm
80 mm
Weight
4.5 kg
5.0 kg
5.5 kg
6.0 kg
Safety
Approvals
See rating plate
Overvoltage category
II for all U
N
Electrical data
Rated voltage
24 V DC
Permitted voltage range
+19.2 V to +28.8 V
Rated current at 24 V DC
1 A
1.8 A
1.5 A
2.0 A
Rated current, load-dependent
0.8 to 1.3 A
1.6 to 2.1 A
1.3 to 1.9 A
1.7 to 2.4 A
Power consumption
1
24 W
41 W
36 W
49 W
1
The power loss generally corresponds to the specified value for power consumption.