Functions and Technical Specifications
4-6
EM 148-FC
Frequency Converter
A5E00065321-03
4.1.3
Error acknowledgment
1. If an error occurs, the drive is put out of operation.
2. After the cause of the error has been detected and eliminated (see Section 3.6),
the error must be acknowledged through a rising edge of control bit 7.
3. The Frequency Converter then goes into the starting lockout state (status bit 6).
4. A rising edge of control bit 0 (AUS1) is required for the restart.
5. Result: Status bit 6 is reset and the motor ramps up.