Channel-specific error messages
You can find more information on the channel-specific diagnosis in Chapter 5 of the
ET 200X Distributed I/O Device manual.
Table 3-4
Error messages in accordance with the PROFIBUS standard
Error number
Error text
Meaning/possible causes
Remedy
00010
B
2
D
Undervoltage
No supply voltage or supply
voltage too low
Check and, if necessary, adjust
the supply voltage
00011
B
3
D
Overvoltage
Supply voltage too high
Check and, if necessary, adjust
the supply voltage
Braking power too high
Increase Ramp-down time
parameter
00100
B
4
D
Overload
Overtemperature in the frequency
converter
Check the ambient temperature
Overcurrent to the motor
Check the mechanical load of the
motor
01001
B
9
D
Error/fault
Internal module fault
Replace the frequency converter
Table 3-5
Vendor-specific error messages
Error number
Error text
Meaning/possible causes
Remedy
10000
B
16
D
Parameter
Module was not parameterized.
Reparameterize the module
assignment
error
The module received incorrect
parameters
Check all the parameters/motor
data and correct, if necessary
10001
B
17
D
No load voltage
(see note
above)
The following voltage is not
applied:
24 VDC load voltage
Adjust the process wiring
11000
B
24
D
Actuator error
Overtemperature of the motor
Check the mechanical load on the
motor (e.g. brake, load)
The thermistor is not connected
Connect the thermistor or disable
the Thermistor monitoring of
motor parameter
Summary of Contents for SIMATIC EM 148-FC
Page 56: ...Functions and Technical Specifications 4 22 EM 148 FC Frequency Converter A5E00065321 03 ...
Page 66: ...Mode of Functioning 5 10 EM 148 FC Frequency Converter A5E00065321 03 ...
Page 70: ...Dimensioned Drawing B 2 EM 148 FC Frequency Converter A5E00065321 03 ...
Page 76: ...4 Product Information on Manual EM 148 FC Frequency Converter Edition 04 2003 A5E00476687 03 ...