815_58300000003806_ara_en_e.doc – 30.01.12
Seite 43 von 67
6.7 Detergent-solution
pump
6.7.1 Removal
►
Unscrew base panel and base plate
►
Press lever (1) to right and disengage
►
Rotate detergent-solution pump forwards (2)
►
After a quarter revolution, remove detergent-solution pump to right
(3)
6.7.2 Installation
►
Insert detergent-solution pump
►
Rotate detergent-solution pump to rear until the locking lever
engages
►
Screw on base plate and base panel