815_58300000003806_ara_en_e.doc – 30.01.12
Seite 41 von 67
6.6
Circulation pump (SICASYM)
6.6.1 Removal
►
Remove side panels and base plate
►
Loosen connection between stainless steel container and plastic
base pan, (2 screws at front and 2 screws at rear)
►
Raise container on the right side and tilt to the left
►
Secure container with an approx. 4 cm thick object
►
Using a screwdriver, press the catch on the right side of the
circulation pump inwards
►
Rotate pump to the right
►