![Siemens SCALANCE XR-300M Compact Operating Instructions Download Page 60](http://html.mh-extra.com/html/siemens/scalance-xr-300m/scalance-xr-300m_compact-operating-instructions_383840060.webp)
Table 7-7
Electrical data: Current consumption and power loss
Device version
(power supply)
Current consumption
Effective power loss
2 x 24 VDC
1.8 A
44 W
1 x 100 to 240 VAC
0.8 to 0.45 A
50 W
Table 7-8
Electrical data: Overcurrent protection
Device version
(power supply)
Overcurrent protection of the power supply
Non-replaceable fuse
2 x 24 VDC
5 A / 125 V
1 x 100 to 240 VAC
3.15 A / 250 V
Table 7-9
Electrical data: Signaling contact
Voltage via signaling contact
24 VDC
Switching capacity (resistive load)
max. 100 mA
Resistor between F1-F2
< 8 Ω
Table 7-10
Plug-in terminal block for connectors of the power supply and signaling contact
Device version
(power supply)
Power supply
Signaling contact
2 x 24 VDC
2 x 4-pin
2 x 2-pin
1 x 100 to 240 VAC
1 x 2-pin
1 x 2-pin
7.3
Cable lengths
Table 7-11
Permitted cable lengths (copper cable - Fast Ethernet)
Cable type
Accessory (plug, outlet, TP cord) Permitted cable length
IE TP torsion cable
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 45 m
+ 10 m TP cord
with IE FC RJ-45 Plug 180
0 to 55 m
IE FC TP Marine Cable
IE FC TP Trailing Cable
IE FC TP Flexible Cable
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 75 m
+ 10 m TP cord
with IE FC RJ-45 Plug 180
0 to 85 m
IE FC TP standard cable
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 90 m
+ 10 m TP cord
with IE FC RJ-45 Plug 180
0 to 100 m
Technical specifications
7.3 Cable lengths
SCALANCE XR-300M
60
Compact Operating Instructions, 11/2019, A5E02661171-15
Summary of Contents for SCALANCE XR-300M
Page 10: ...Introduction SCALANCE XR 300M 10 Compact Operating Instructions 11 2019 A5E02661171 15 ...
Page 12: ...Safety notices SCALANCE XR 300M 12 Compact Operating Instructions 11 2019 A5E02661171 15 ...
Page 82: ...Index SCALANCE XR 300M 82 Compact Operating Instructions 11 2019 A5E02661171 15 ...