Technical Specifications
5
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
When determining cable lengths, make sure the minimum input voltage for the pow-
er supply is provided at the power source.
Hazardous Environments
Input Voltage
Power Sup-
ply Type
Minimum
Maximum
Nominal
Internal
Fuse Rating
Isolation
Maximum
Power Con-
sumption
LO
11.1 VDC
55 VDC
12 VDC, 24
VDC, 48 VDC
5 A
1.5 kVDC
13.4 W
100 VDC
270 VDC
125 VDC,
250 VDC
3.15 A
5 kVDC
15.3 W
HI
100 VAC
240 VAC
110 VAC,
220 VAC
3.15 A
5 kVDC
15.5 W
Current consumption may vary based on configuration.
Non-Hazardous Environments
Input Voltage
Power Sup-
ply Type
Minimum
Maximum
Nominal
Internal
Fuse Rating
Isolation
Maximum
Power Con-
sumption
LO
10 VDC
60 VDC
12 VDC, 24
VDC, 48 VDC
5 A
1.5 kVDC
13.4 W
88 VDC
300 VDC
125 VDC,
250 VDC
3.15 A
5 kVDC
15.3 W
HI
85 VAC
264 VAC
110 VAC,
220 VAC
3.15 A
5 kVDC
15.5 W
Current consumption may vary based on configuration.
RUGGEDCOM RSG909R
Installation Manual, 02/2020, C79000-G8976-1388-09
29