Communication Ports
4.2 Copper Ethernet Ports
IMPORTANT
RNA ports A and B must operate at the same speed. Inconsistent speed in these
ports will generate an alarm. Make sure to use SFPs with compatible speeds on ports
A and B.
4.2
Copper Ethernet Ports
The RUGGEDCOM RSG909R supports multiple 10/100/1000Base-TX Ethernet ports
that allow connection to standard Category 5 (CAT-5) shielded twisted-pair cables
with RJ45 male connectors.
WARNING
Electric shock hazard – risk of serious personal injury and/or equipment inter-
ference
When shielded cables are used, make sure the shielded cables do not form a ground
loop via the shield wire and the RJ45 receptacles at either end. Ground loops can
cause excessive noise and interference, but more importantly, create a potential
shock hazard that can result in serious injury.
LEDs
Each port features an LED that indicates the state of the port.
State
Description
Green (Solid)
Link established
Green (Blinking)
Link activity
Off
No link detected
Pin-Out
The following is the pin-out for the RJ45 male connectors:
1
8
Figure 4.3
RJ45 Ethernet Port Pin Config-
uration
Name
Pin
10/100Base-
TX
1000Base-
TX
Description
1
RX+
BI_DB+
Receive Da-
ta+ or Bi-Di-
rectional
2
RX-
BI_DB-
Receive Da-
ta- or Bi-Di-
rectional
3
TX+
BI_DA+
Transmit
Data+ or Bi-
Directional
RUGGEDCOM RSG909R
Installation Manual, 02/2020, C79000-G8976-1388-09
27