Certification
6.1.2 CSA/Sira
•
ANSI/UL 60079-15:13
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Type of Protection
"n"
The device is marked with a CSA symbol that indicates compliance with both Canadi-
an and U.S. requirements.
C
US
It is specifically approved for use in Division 2 and Zone 2 hazardous locations with
the following markings:
• Class I, Division 2, Groups A, B, C, D T4
• Ex nA nC IIC T4 Gc
• Class I, Zone 2, AEx nA nC IIC T4 Gc
This device meets the requirements of the following International standards under
certificate IECEx CSA 18.0007X:
•
IEC 60079-0:2011
Explosive Atmospheres – Part 0: Equipment – General Requirements
•
IEC 60079-15:2010
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Construction, Test
and Marking of Type of Protection "n" Electrical Apparatus.
It is specifically approved for use in Zone 2 hazardous locations with the following
markings:
• Ex nA nC IIC T4 Gc
6.1.2
CSA/Sira
When marked with the following ATEX marking, this device is approved for use in
Zone 2 hazardous locations under certificate Sira 18ATEX4069X.
Note
For the maximum ambient temperature, refer to the hazardous location label affixed
to the device.
II 3 G Ex nA nC IIC T4 Gc
36
RUGGEDCOM RSG909R
Installation Manual, 02/2020, C79000-G8976-1388-09