RUGGEDCOM RS416
Installation Guide
Chapter 6
Certification
EMC and Environmental Type Tests
41
Description
Test Levels
Signal ports
2.5 kV common mode @ 1MHz
DC Power ports
2.5 kV common and differential mode @ 1MHz
Oscillatory
AC Power ports
2.5 kV common and differential mode @ 1MHz
Signal ports
5 kV (Failsafe Relay)
DC Power ports
5 kV
HV Impulse
AC Power ports
5 kV
Signal ports
2 kVAC (Failsafe Relay)
DC Power ports
1.5 kV
Dielectric Strength
AC Power ports
2 kV
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing),
55 °C (131 °F), 96 hours
IEC 60068-2-6
Vibration
2 g @ 10-150 Hz
Class 2
IEC 60068-2-27
Shock
30 g @ 11 ms
Class 2