Chapter 6
Certification
RUGGEDCOM RS416
Installation Guide
40
EMC and Environmental Type Tests
Test
Description
Test Levels
Severity Levels
AC Power ports
10 V
3
Earth
ground ports
10 V
3
100 A/m
Note
a
IEC 61000-4-8
Magnetic Field
Enclosure ports
1000 A/m for 3 s
5
DC Power ports
30% for 0.1 s, 100% for 0.05 s
IEC 61000-4-29
IEC 61000-4-11
Voltage Dips and Interrupts
AC Power ports
30% for 1 period, 100% for 5
periods, 100% for 250 periods
Signal ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
3
DC Power ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
3
IEC 61000-4-12
Damped Oscillatory
AC Power ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
3
Signal ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-16
Mains Frequency Voltage
DC Power ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-17
Ripple on DC Power Supply
DC Power ports
± 15%
4
Signal ports
2 kVAC (Fail-Safe Relay output)
DC Power ports
1.5 kV
Dielectric Strength
AC Power ports
2 kV
Signal ports
5 kV (Fail-Safe Relay Output)
DC Power ports
5 kV
IEC 60255-5
HV Impulse
AC Power ports
5 kV
a
Siemens specified severity level.
IEEE 1613 EMC Immunity Type Tests
NOTE
The RS416 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for
copper ports.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure ports
35 V/m
Signal ports
± 4 kV @ 2.5 kHz
DC Power ports
± 4 kV
AC Power ports
± 4 kV
Fast Transient
Earth ground ports
± 4 kV