System mode
15
Siemens AG
04.2010
9 System
mode
9.1
Activate System mode
Starting in Stand-alone mode, three parameters must be entered to set the
RF30-EM in System mode:
4-digit Segment ID
2-digit Address
8-digit Installation key
CAUTION
Remember to change the Administrator code for safety reasons
If the battery is low the door can be opened with the default Administrator code.
1.
Change the Administrator code. See section 8 Change Administrator code.
2.
Check in the SiPass/Bewator Entro software which Segment ID, Address and
installation key is used in the SR35i.
3.
Press B.
4.
Enter the 6-digit Administrator code.
5.
Enter A80.
6.
Enter the 4-digit Segment ID.
7.
Enter the 2-digit Address. (01 - 32)
8.
Enter the 8-digit Installation key.
9.
Press A.
The RF30-EM will operate in System mode. If any other key than A is pressed
the RF30-EM returns to Stand-alone Administrator mode.
If any of these steps is not performed within 20 seconds the RF30-EM returns to
Administrator mode.
NOTE
If you make errors in steps 6 to 8, press any other key than A in step 9 and start over from step 5.