PXC3.E... Room automation stations
CM1N9203en_05
Building Technologies
2015-11-23
Use
Starting with Desigo V5, PXC3 series room automation stations with Total Room
Automation applications (TRA) can be used for buildings with more sophisticated
requirements on functionality and flexibility. TRA is used when several disciplines
(HVAC, lighting, shading) are combined to form one total solution and when total
flexibility is required. TRA is perfect for solutions optimizing energy (class A)
without loss of comfort.
Functions
A PXC3 series room automation station can assume control for multiple rooms.
These programmable room automation stations provide the infrastructure to
provide and process system- and application-specific functions.
Desigo
version
Product No.
Stock No.
Function
Number of I/O
data points
KNX PL-
Link
TX-I/O modules
DALI bus
V6
PXC3.E16A-
100A
S55376-C118
DALI applications
only
64
3)
- -
- -
max. 64
ballasts
4)
PXC3.E72-100A
S55376-C130
typically 4 rooms
typically 8 room
segments
1)
140
3)
max. 64
devices
max. 72 physical
I/O points
- -
PXC3.E72A-
100A
S55376-C131
typically 4 rooms
typically 8 room
segments
1)
140
3)
max. 64
devices
max. 72 physical
I/O points
max. 64
ballasts
4)
PXC3.E75-100A
S55376-C132
typically 8 rooms
typically 16 room
segments
1)
280
3)
max. 64
devices
max. 200 physical
I/O points
- -
PXC3.E75A-
100A
S55376-C133
typically 8 rooms
typically 16 room
segments
1)
280
3)
max. 64
devices
max. 200 physical
I/O points
max. 64
ballasts
4)
V5.1
V5.1SP
2)
PXC3.E72
S55376-C100
typically 4 rooms
typically 8 room
segments
2)
140
3)
max. 64
devices
max. 72 physical
I/O points
- -
PXC3.E72A
S55376-C101
typically 4 rooms
typically 8 room
segments
2)
140
3)
max. 64
devices
max. 72 physical
I/O points
max. 64
ballasts
4)
PXC3.E75
S55376-C102
typically 8 rooms
typically 16 room
segments
2)
280
3)
max. 64
devices
max. 200 physical
I/O points
- -
PXC3.E75A
S55376-C103
typically 8 rooms
typically 16 room
segments
2)
280
3)
max. 64
devices
max. 200 physical
I/O points
max. 64
ballasts
4)
1)
Architectural building grid (also called room axis).
2)
If V6 applications are loaded into a V5.1 device, less rooms are supported,
because V6 applications require more memory space.
To find out, DCM features the Load calculation tool.
3)
Total number of data point used by TX-I/O, KNX PL-Link and DALI.
For details see Desigo Technical principles CM110664, chapter 18.
4)
Commercially available DALI -ballasts with a DALI address.
Control of several
rooms
Variants