Summary of Contents for MindConnect IoT2040

Page 1: ..._ ___________________ MindSphere Getting Connected to MindSphere Getting Started 05 2018 Safety Notes 1 Introduction 2 Overview of MindConnect Elements 3 Mounting and installing MindConnect Elements 4 Connecting MindConnect Elements 5 Onboarding MindConnect Elements 6 Configuring data in Asset Manager 7 Visual analysis of assets in Fleet Manager 8 Appendix A ...

Page 2: ...ersonnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products ma...

Page 3: ...onnect IoT2040 20 4 3 1 Permitted mounting positions and surrounding temperature 20 4 3 2 Mounting types 21 4 4 LED lights of MindConnect Elements 22 4 4 1 LED lights of MindConnect Nano 22 4 4 2 LED lights of MindConnect IoT2040 24 4 4 3 Troubleshooting 26 5 Connecting MindConnect Elements 31 5 1 Commissioning MindConnect Element 31 5 2 Firewall Proxy rules for MindSphere 35 5 3 Connecting MindCo...

Page 4: ... Adding datasource 58 7 3 2 Adding datapoints 60 7 4 Datamapping 62 8 Visual analysis of assets in Fleet Manager 67 8 1 Overview visual analysis 67 8 2 Selecting assets 67 8 3 Viewing aspects 70 8 4 Viewing events 72 A Appendix 75 A 1 Overview of datatypes 75 A 1 1 Overview of S7 datatypes 75 A 1 2 Overview of OPC UA datatypes 78 A 2 Technical specifications of MindConnect Nano 81 A 3 Technical sp...

Page 5: ... expansions may violate safety rules and regulations regarding radio interference suppression If you install or exchange system expansions and damage your device the warranty becomes void Note the following for system expansions Only install system expansion devices designed for this device Contact your technical support team or the team where you have purchased your PC to find out which system ex...

Page 6: ...ntical battery or types recommended by the manufacturer Do not throw lithium batteries into fire do not solder on the cell body do not recharge do not open do not short circuit do not reverse polarity do not heat above 100 C and protect from direct sunlight moisture and condensation Strong high frequency radiation NOTICE Observe immunity to RF radiation The device has an increased immunity to RF r...

Page 7: ...dConnect Nano To the extent there is a conflict between these terms and the open source specific license terms such terms shall prevail with regard to the open source software Industrial Security Siemens provides products and solutions with industrial security functions that support the secure operation of plants systems machines and networks In order to protect plants systems machines and network...

Page 8: ...e device is tested and certified on the basis of the technical standards In rare cases functional restrictions can occur during plant operation Validate the correct functioning of the plant to avoid functional restrictions Note Use in an industrial environment without additional protective measures This device was designed for use in a normal industrial environment according to IEC 60721 3 3 ...

Page 9: ...ecommended Scope of validity of this document This manual is valid for MindSphere and MindConnect Elements MindConnect Nano MindConnect IoT2040 Convention The term device is used to refer to MindConnect Nano and MindConnect IoT2040 The terms for MindSphere can be found in Glossary in the Appendix of this documentation The configuration parameters should be extracted out of the text or tables and d...

Page 10: ...hrough typical steps involved in configuring MindConnect Elements and your asset data You will become familiar with the tools that MindSphere provides for configuration and visualization of assets and aspects 2 3 Functional overview of MindSphere This part of Getting Started outlines the functional overview of MindSphere MindSphere offers the means to monitor asset status as well as support mainte...

Page 11: ...rowser e g Google chrome or Firefox for online user interface Internet connection for MindConnect Nano IoT2040 device Provide standard HTTPS capabilities for MindConnect Nano IoT2040 outbound HTTPs connection s on port 443 Link to the online Launchpad with user and password data as supplied by Siemens Device PC tablet etc with minimum screen resolution of 1024x768 Configuring steps Prepare MindCon...

Page 12: ...te an asset in Asset Manager 3 Configure the datapoints you want to use 4 MindConnect Nano IoT2040 receives the configuration from MindSphere via an existing Internet connection 5 MindConnect Nano IoT2040 starts the data acquisition 6 The timeseries can be displayed in Fleet Manager Visual analysis of assets with Fleet Manager 1 Monitor assets in different views 2 Monitor aspects and events ...

Page 13: ...fer it encrypted to MindSphere MindConnect Nano MindConnect Nano is a preconfigured Industrial PC that allows connectivity to MindSphere The device supports the transmission of data encrypted through a secured Internet connection to MindSphere MindConnect Nano allows fast and easy IoT connectivity of machines and systems For more information refer to chapter Technical specifications of MindConnect...

Page 14: ...ed for collecting and transferring data to MindSphere in smaller production environments The device supports the transmission of encrypted data over a secured Internet connection to enable cloud based applications and services For more information refer to chapter Technical specifications of MindConnect IoT2040 Page 84 The following graphic shows the MindConnect IoT2040 ...

Page 15: ...Overview of MindConnect Elements Getting Connected to MindSphere Getting Started 05 2018 15 ...

Page 16: ......

Page 17: ...e at its installation location 4 Keep the original packaging in case you have to transport the unit again Note Damage to the device during transport and storage If a device is transported or stored without packaging shocks vibrations pressure and moisture may impact the unprotected unit Damaged packaging indicates that ambient conditions may have already had a massive impact on the device The devi...

Page 18: ...ce for immediate repair NOTICE Damage from condensation If the device is subjected to low temperatures or extreme fluctuations in temperature during transportation for example in cold weather moisture could build up on or inside the HMI device Moisture causes a short circuit in electrical circuits and damages the device In order to prevent damage to the device proceed as follows Store the device i...

Page 19: ...re permitted Horizontal mounting position The horizontal mounting position is the preferred position Maximum surrounding temperature is 60 C Vertical mounting position Maximum surrounding temperature is 50 C Note 50 C Install in RAL RAL Restricted Access Location e g a lockable cabinet Free space around the device Please make sure there s enough empty space around the device Above the device 50 mm...

Page 20: ...nect IoT2040 4 3 1 Permitted mounting positions and surrounding temperature The following mounting positions and surrounding conditional temperature are permitted Horizontal mounting position The horizontal mounting position is the preferred position Maximum surrounding temperature is 50 C Vertical mounting position Maximum surrounding temperature is 50 C Note 50 C Install in RAL RAL Restricted Ac...

Page 21: ...gh space around the device Above the device 50 mm Below the device 50 mm 4 3 2 Mounting types Note Ensure that the mounting surface on the wall can bear four times the total weight of the device including attached elements Use only the anchors and screws specified in the operating instructions The following mounting types of the device are possible Mounting on rails Figure 4 2 Mounting on rails ...

Page 22: ...tting Started 05 2018 Wall mounting Figure 4 3 Wall mounting 4 4 LED lights of MindConnect Elements 4 4 1 LED lights of MindConnect Nano LED lights The LED lights status provide information on efficient self diagnostics The following graphics show the LED lights of the MindConnect Nano Figure 4 4 LED lights bottom view 1 ...

Page 23: ...in progress GREEN MindConnect Nano is onboarded to MindSphere L2 ERROR Blinking ORANGE Firmware update active ORANGE No connection to the datasources For explanation of possible problems and respective solution please refer to the chapter Troubleshooting Blinking RED Data loss For explanation of possible problems and respective solution please refer to the chapter Troubleshooting RED Firmware upda...

Page 24: ...MindSphere Figure 4 6 USER LED light The following table describes the device behavior associated when a different USER LED status is displayed Name Status Description USER LED Fast ORANGE Blinking USB STICK ACTIVE Network diagnostics are running Configuration file is being read USER LED RED Blinking USB STICK ERROR Read error USB flash drive is damaged Configuration file is invalid damaged illegi...

Page 25: ...light flashes green for a short time to indicate the onboarding process otherwise is orange GREEN Blinking ONBOARDING IN PROGRESS USER LED ORANGE Flashing ONBOARDING FAILED LED flashes red for a short time to indicate onboarding is falling Possible reason Server error OBT is no longer valid For explanation of possible problems and respective solution please refer to the chapter Troubleshooting GRE...

Page 26: ...igured IP and Proxy are valid Check physical connection your company s router Ethernet cables etc No internet connection MCN L2 ERROR LED IoT2040 USER LED ORANGE Although an asset is onboarded no timeseries are uploaded to Fleet Manager and Visual Analyzer No connection to datasource Check the connection between MindConnect Nano and datasources Plant Network ports and cables S7 OPC UA Server The a...

Page 27: ... IP address User Authentication can be required MCN L2 ERROR LED RED IoT2040 USER LED Firmware update error Technical problems with a new version of firmware Incorrect firmware type Certificate problems Authentication problems etc Make sure that you are using the correct firmware type MindConnect Nano IoT2040 MindConnect Nano IoT2040 will automatically restart and then firmware update will be carr...

Page 28: ... only for 7 days If it is expired use the Asset Configuration to export a new valid configuration to your USB stick Check Asset Configuration and reconfigure if it is required and export a new configuration to USB stick MCN L3 MAINT LED blinking RED IoT2040 USER LED blinking Problems with USB stick Incorrect formatting of USB stick no FAT or FAT32 USB stick is damaged Write error USB stick is writ...

Page 29: ...ile on the USB stick The configuration file is invalid or not copied to the USB stick Remove and plug an USB stick into MindConnect Nano Check the diagnosis file on the USB stick Check the name of the configuration file It must have MindConnect Nano ID Do not change the name of the downloaded file Check whether the directory is valid Configuration file must be in the root directory of the USB stic...

Page 30: ......

Page 31: ...cross section of 0 75 mm to 2 5 mm A slotted screwdriver with a 3 mm blade NOTICE Power supply requirements MindConnect Nano should only be connected to a 24 V DC to power supply which satisfies the requirements of safety extra low voltage SELV according to IEC EN DIN EN UL 60950 1 MindConnect IoT2040 should only be connected to a 9 36 V DC power supply which meets the requirements of safe extra l...

Page 32: ...er 70 C Any unprotected contact may cause burns Avoid direct contact during operation of the device Touch the device only with appropriate protective gloves 1 Switch off the power supply on the device 2 Connect the cores of the power supply 3 Insert the terminal at the indicated position The graphic shows how to connect the power supply for MindConnect Nano Figure 5 1 Connecting the power supply f...

Page 33: ...issioning MindConnect Element Getting Connected to MindSphere Getting Started 05 2018 33 The graphic demonstrates the steps how to connect the power supply for MindConnect IoT2040 Figure 5 2 Connecting the power supply for MindConnect IoT2040 ...

Page 34: ... position I ON The PC ON WD LED lights up green For MindConnect IoT2040 switch on the power supply The graphic shows the PWR LED lights up green Figure 5 3 Power on a power supply for MindConnect IoT2040 Result MindConnect Nano IoT2040 is now prepared and you can onboard it to MindSphere If the green light does not appear refer to section Troubleshooting Page 26 for more information about LED mess...

Page 35: ...resses based on the context of the caller and the state of the backend 5 3 Connecting MindConnect Nano to MindSphere network The following options are available for integrating the device in existing or planned system environments and networks X63 port PN IE LAN X1 P1 port PN IE LAN X2 P1 port Figure 5 4 Connections of MindConnect Nano The following table explains each connection port in detail Po...

Page 36: ...Connected to MindSphere 36 Getting Started 05 2018 Procedure Before you start onboarding connect MindConnect Nano to MindSphere as follows Insert Ethernet cable into the port labeled with X1 P1 to connect MindConnect Nano to MindSphere Figure 5 5 Connecting the port X1 P1 for Internet MindSphere ...

Page 37: ... LAN X1 P1 port PN IE LAN X2 P1 port Figure 5 6 Interfaces of MindConnect IoT2040 The following table explains each connection port in detail Port Description X60 USB 2 0 port high current Configuration file on USB stick Required during onboarding process PN IE LAN X1 P1 RJ45 Ethernet connection 1 for 10 100 1000 Mbps Access to the Internet to MindSphere Required to start onboarding process PN IE ...

Page 38: ...t MindConnect IoT2040 to MindSphere as follows Insert Ethernet cable for Internet into the port labeled with X1 P1 Figure 5 7 Connecting the port X1P1 for internet MindSphere Note During the onboarding process only one USB stick is supported Do not plug in more than one USB stick The recommended USB port is the USB port with label X60 ...

Page 39: ... created in Asset Manager The configuration has been transferred via USB stick to the MindConnect Element Procedure To connect the MindConnect Element to your plant network or asset insert the Ethernet cable into the port labeled with X2 P1 The following graphic shows the connecting port of the MindConnect Nano Figure 5 8 Connecting Ethernet Port X2 P1 MindConnect Nano The following graphic shows ...

Page 40: ......

Page 41: ...cribed in the following procedure Requirements MindConnect Nano IoT2040 is connected to the Internet and powered on The connection cable for the Internet is correctly plugged into the Ethernet port for the Internet MindSphere MindConnect Nano IoT2040 is connected to asset or plant network You have received the link to the MindSphere UI with credentials user and password data A customer account is ...

Page 42: ...for boxes that were already connected to MindSphere V2 SAP 1 Set the MindConnect back to factory settings 2 Create a ConBox_Commands json file with your favorite code editor Content of ConBox_Commands json Commands Cmd DoFactoryReset DeviceID MindConnectID Note MindConnectID has to be replaced with the serial number of the device 3 Store the json file on a USB stick 4 Plug the USB stick in the Min...

Page 43: ...ry siemens com cs ww en view 109745561 Firmware download MindConnect IoT2040 https support industry siemens com cs ww en view 109745562 2 Unzip the firmware on your local machine 3 Copy the unzipped files to a USB stick 4 Insert the USB stick into the MindConnect Element and wait until the firmware update is complete Update carried out ERROR LED flashes orange MindConnect Element reboots MAINT LED...

Page 44: ...ded via mail by the Siemens AG The MindSphere landing page for login will appear 2 Log in to MindSphere with your Webkey login credentials You will be redirected to your personal MindSphere Launchpad Depending on your offering the Launchpad Icons will be displayed Note MindSphere supports English and German languages Therefore it is recommended to set the browser default to English if you use a di...

Page 45: ...eed to create an asset Procedure To create an asset proceed as follows 1 Select Asset Manager from the Launchpad 2 Click Assets in the navigation area 3 To create a new asset click The asset type overview window is opened 4 Select the respective asset type for your MindConnect Element e g MindConnect Nano 5 Enter a name and the data for the asset e g Windmill1 6 Confirm the entries with Save ...

Page 46: ...arding MindConnect Elements 6 4 Creating an asset Getting Connected to MindSphere 46 Getting Started 05 2018 Result The new asset is available at the asset list The following graphic shows the created asset ...

Page 47: ...connection Within enabling the connection you can assign a MindConnect Element to an asset Procedure To enable the connection to the MindConnect Element proceed as follows 1 Select the asset in the Asset tab 2 Click on the asset icon e g MindConnect Nano The Create MindConnect screen appears 3 Enter the unique ID from your hardware Result You have enabled the connection to the MindConnect Element ...

Page 48: ...gured to connect MindConnect Nano IoT2040 to MindSphere Contact your IT administrator for details on your local network settings After enabling the connection to the MindConnect Element you can edit the network configuration You can enter either a static IP address or use DHCP The last option is possible if there is a DHCP server available in your company network Procedure To configure the network...

Page 49: ...r the proxy data area Communication Settings if necessary and click Save In this case contact your network administrator to get the proxy data Note If nothing else is configured manually MindConnect Nano IoT2040 will try to obtain IP addresses for both adapters via DHCP 6 Click on Save to complete the configuration 6 7 Transferring configuration to MindConnect Element Requirement A standard USB de...

Page 50: ...es security relevant information Take care of the USB stick and the information flow from MindSphere to USB stick and from USB stick to the MindConnect Element Delete the USB stick after use To export the configuration follow these steps 1 In the MindConnect settings click The following graphic shows the Edit MindConnect screen 2 Click on Download Onboarding Key 3 Save the downloaded file to the r...

Page 51: ...ck from the MindConnect Element 6 Check the status of the MindConnect Element at the Overview Result The connection status in Asset Manager at the overview has changed to Onboarded The configuration of the asset has been transferred to the MindConnect Element The connection between the MindConnect Element and MindSphere is established Once MindConnect Nano IoT2040 is onboarded the connection to yo...

Page 52: ...Onboarding MindConnect Elements 6 7 Transferring configuration to MindConnect Element Getting Connected to MindSphere 52 Getting Started 05 2018 ...

Page 53: ...o enable datamapping Adding a datasource and datapoints Page 58 The data source defines the reading of the data from the MindConnect Element Datamapping Page 62 In this final step you map the data of the MindConnect Element to the aspects and variables in MindSphere 7 1 Creating aspects and variables To use the data of your MindConnect Element in MindSphere you need to create aspects and variables...

Page 54: ...new aspect click 3 Enter your Tenant ID for the aspect e g idevdoc generator Note All custom aspects and types must be named as TenantID xxx 4 Enter a name and describtion for the aspect e g Generator 5 Follow these steps for each variable e g RotationSpeed Enter variable data Note The units and data types specified here will need to match exactly also case sensitive with the physical data source ...

Page 55: ...nfiguring data in Asset Manager 7 1 Creating aspects and variables Getting Connected to MindSphere Getting Started 05 2018 55 Result The new aspect type with its variables is available in the aspect list ...

Page 56: ...ype An asset type is a pre configured template for an asset The asset type predefines which aspects are integrated into the template You have to link aspects to an asset type to enable the connection to a datapoint Requirement You have created an aspect Procedure To create an asset type proceed as follows 1 Click on the Types tab in Asset Manager 2 Click on BasicDevice 3 To create a new asset type...

Page 57: ... Enter ID and name for asset type e g Windmill Note The ID must be named as TenantID xxx 5 Select an aspect type from the dropdown menu e g Generator You can find additional information on aspects in the chapter Creating aspects and variables Page 53 6 Enter an aspect name and click Add 7 To save the asset type click Save ...

Page 58: ...tasource and datapoints 7 3 1 Adding datasource To receive the data of your MindConnect Element you need to add a datasource The datasource specifies the protocol and reading cycle that is used to transfer the data from your asset to the MindConnect Element Within the datasource you enter the IP address of the asset inside of your network Requirement You have created an asset and an aspect You hav...

Page 59: ... 1 Click on the asset in the Assets tab e g Windmill 2 Click on the asset icon e g MindConnect Nano 3 Click Add new Datasources The window to enter the protocol data is opened Note The default reading cycle is 86400 seconds which is one day You can find additional information on protocol datatypes in the chapter Overview of datatypes Page 75 4 Enter datasource data and confirm with Accept 5 To sav...

Page 60: ...cally Examples of a datapoint are temperature or pressure Within MindSphere you add datapoints to a datasource to collect the data for example from a control unit In the next step you have to link the datapoints of a datasource with the respective variables of an aspect Requirement You have created a datasource Procedure To add a datapoint to a datasource e g RotationSpeed follow these steps 1 Cli...

Page 61: ...l need to match exactly with the aspects and variables If they are different the aspect cannot be connected to the datapoint The protocol datatypes specify the Datapoint Address You can find additional information on protocol datatypes in the chapter Overview of datatypes 6 Confirm with Accept 7 To save the added datapoint in Edit Mode click Save Result The new datapoint is available at the dataso...

Page 62: ...t Element you have to map them to the respective variables of an aspect Requirement You have now created an asset based on your desired aspect and asset type Procedure To map a variable to a datapoint e g RotationSpeed follow these steps 1 Click on the asset in the Assets tab e g Windmill1 2 Click on the asset icon e g MindConnect Nano 3 Click View Datamapping 4 Select the aspect e g Generator 5 S...

Page 63: ...amapping Getting Connected to MindSphere Getting Started 05 2018 63 7 Select the previously created asset type and click Accept e g Windmill Note You can find additional information on asset types in the chapter Creating an asset type Page 56 ...

Page 64: ...to link e g RotationSpeed Note Only units and data types that match exactly with the aspects and variables are available If they are different the aspect can t be connected to the datapoint also case sensitive 9 To link the variable click Accept Result The datapoint is now mapped to the variable The following graphic shows a mapped variable ...

Page 65: ...Configuring data in Asset Manager 7 4 Datamapping Getting Connected to MindSphere Getting Started 05 2018 65 ...

Page 66: ......

Page 67: ...set Manager Procedure To see the visualized data in Fleet Manager you can proceed as follows 1 Select a required asset to view its data Page 67 2 View aspects of a selected asset Page 70 3 View events of a selected asset Page 72 8 2 Selecting assets Fleet Manager offers the means for viewing and simple searching sorting filtering of assets You access Fleet Manager via the MindSphere Launchpad Requ...

Page 68: ...68 Getting Started 05 2018 3 To see the map view click 4 To quickly find the created asset e g Windmill choose one of the following features Select the asset that is linked to your aspect and asset type Enter a required text in the searching box Figure 8 1 Finding the asset via the searching text ...

Page 69: ...ts Getting Connected to MindSphere Getting Started 05 2018 69 Or click the Filter sort button to restrict the asset list Figure 8 2 Finding the asset Filter sort Result The navigation displays the selected asset that corresponds to the search or filter parameters ...

Page 70: ...xtension Requirement You have created aspects in Asset Manager Procedure To view variables of aspects in the Aspect extension proceed as follows 1 In the right hand side of Fleet Manager click the Aspects extension icon The Aspects extension opens on the right hand side 2 Select and expand an aspect e g Generator Aspect Generator is opened You can set a time frame Time picker day week and month an...

Page 71: ...Visual analysis of assets in Fleet Manager 8 3 Viewing aspects Getting Connected to MindSphere Getting Started 05 2018 71 Result The Aspects extension shows the chosen aspect of an asset ...

Page 72: ...ria You can also assign a specific status to events You can find additional information on creating events in the Fleet Manager documentation Requirements You have created assets in Asset Manager Events have been created and are already available Procedure 1 Select the required asset e g Windmill in the left hand side of the window 2 In the right hand side click the Events extension icon 3 Click t...

Page 73: ...Visual analysis of assets in Fleet Manager 8 4 Viewing events Getting Connected to MindSphere Getting Started 05 2018 73 ...

Page 74: ......

Page 75: ...ng from offset 24 of datablock 15 DB15 DBDWORD24 Reads a double word starting from offset 24 of datablock 15 DB15 DBDINT28 Reads a double int starting from offset 28 of datablock 15 DB15 DBREAL32 Reads a floating point number starting from offset 32 of datablock 15 DB15 DBSTRING10 Reads a string starting from offset 12 10th byte is maximum string length 254 and 11th byte is actual string length If...

Page 76: ...s Counter value of hardware DB Datablock Reads datablock value from hardware DI Instance Data Reads data directly from hardware Area Number S7 datapoint addresses must contain area number e g DB10 10 datablock Variable Types Area types other than timer and counter must contain a variable type Type Length X Bit Bool 1 B Byte Unsigned 1 byte W Word Unsigned 2 bytes D Double Word Unsigned 4 bytes CHA...

Page 77: ...ength is specified the default setting is 254 characters Datatype Examples of format used STRING 2 AB STRING 55 The character string can consist of up to 55 characters Note You must enclose your character string in single quotation marks The following example shows the byte order when specifying the datatype STRING 4 with the output value AB Tod TIME_OF_DAY Time 32 Time is in steps of 1 ms TOD 0 0...

Page 78: ...aceIndex IdentifierType Identifier OPC UA Client Driver addresses have the following syntax ns For more information refer to the table below Field Description NamespaceIndex The index of the OPC UA Server namespace in which the address resides If the index is 0 the entire ns clause is omitted IdentifierType The type of address OPC UA supports the following four address types i A numeric address re...

Page 79: ...dentifierType String Identifier Counter1 Note String for Identifier The string you enter at the four Identifier will be case sensitive Numeric Numeric IdentifierType Example ns id i number ns 0 i 3190 OR Attribute NodeId Value NodeId NamespaceIndex 0 IdentifierType Numeric Identifier 3190 BaseEventType_LocalTime Guid Guid IdentifierType Example ns id g guid ns 1 g 0d4e10fa b9e1 4842 bca6 887c7d8c3...

Page 80: ...SByte int USINT Byte int INT Int16 int UINT UInt16 int DINT Int32 int UDINT UInt32 int LINT Int64 long ULINT UInt64 long BYTE Byte int WORD UInt16 int DWORD UInt32 int LWORD UInt64 long REAL Float double LREAL Double double STRING String string CHAR Byte int WSTRING String string WCHAR UInt16 int DT DATE_AND_TIME DateTime n a DATE DateTime n a TOD TIME_OF_DAY DateTime n a TIME Double double Note N...

Page 81: ...voltage Type of supply voltage 24 V Current consumption max 1 8 A at 24 V Mains buffering Mains voltage failure stored energy time 20 ms Interfaces USB port 1x USB 3 0 3x USB 2 0 PCIe slot 1x PCIe x1 Disabled serial interface 1x COM Disabled Video interfaces Graphics interface 1x DisplayPort Disabled Industrial Ethernet Industrial Ethernet interface 2x 1000 Mbit RJ45 Monitoring functions Status LE...

Page 82: ... m for 80 1000 MHz and 1 4 2 GHz 80 AM acc to IEC 61000 4 3 3 V m for 2 2 7 GHz 80 AM acc to IEC 61000 4 3 10 V m for 10 kHz 80 MHz 80 AM acc to IEC 61000 4 6 Interference immunity to magnetic fields Interference immunity to magnetic fields at 50 Hz 100 A m to IEC 61000 4 8 Emission of conducted and non conducted interference Interference emission via line AC current cables EN 61000 6 3 EN 61000 6...

Page 83: ...ty Relative humidity Tested according to IEC 60068 2 78 IEC 60068 2 30 Operation 5 to 80 at 25 C no condensation Storage 5 to 95 at 25 C no condensation Vibrations Vibration load in operation Tested to DIN IEC 60068 2 6 10 Hz to 58 Hz 0 075 mm 58 Hz to 200 Hz 9 8 m s 1 g Shock testing Shock load during operation Tested according to IEC 60068 2 27 150 m s 11 ms Software MindConnect Software Pre ins...

Page 84: ...ection accepted SSL TLS encryption of data in transit to MindSphere Installation type mounting Design IoT Gateway built in unit Mounting DIN rail wall mounting Supply voltage Type of supply voltage DC 9 36 V no galvanic isolation Mains buffering Mains voltage failure stored energy time 5 ms Interfaces USB port 1x USB 2 0 1x USB client Connection for keyboard mouse USB USB serial interface 2x COM p...

Page 85: ... 4 5 surge length 30 m Interference immunity on signal cables 30m 2 kV in accordance with IEC 61000 4 4 burst length 30 m Interference immunity against voltage surge Asymmetric interference 2 kV acc to IEC 61000 4 5 surge asymmetric Symmetric interference 1 kV acc to IEC 61000 4 5 surge symmetric Interference immunity to magnetic fields Interference immunity to magnetic fields at 50 Hz 100 A m to ...

Page 86: ... 8 m s Shock testing Shock load during operation Tested according to IEC 60068 2 27 150 m s 11 ms Software MindConnect Software Pre installed MindConnect Software Dimensions Width 144 mm Height 90 mm Depth 53 mm A 4 Firewall Settings It is recommended to use a firewall between the Internet and the MindConnect Elements this is also recommended for communication to the automation network In the dire...

Page 87: ...ix A 4 Firewall Settings Getting Connected to MindSphere Getting Started 05 2018 87 Production Machine Network Corporate Office Network with route to the internet or direct internet access e g via a DSL modem ...

Page 88: ...lectrostatic sensitive device ESD Electrostatic Sensitive Device as a common international designation Electrostatic sensitive devices can be labeled with an appropriate symbol NOTICE Damage to ESD from touch Electrostatic sensitive devices ESD can be destroyed by voltages which are far below the human perception limit If you touch a component or electrical connections of a module without discharg...

Page 89: ...ic voltages with which a person is charged depending on humidity and material These values conform to the specifications of IEC 61000 4 2 Voltage Synthetic materials Wool Antistatic materials such as wood or concrete Relative humidity NOTICE Grounding measures There is no equipotential bonding without grounding An electrostatic charge is not discharged and may damage the ESD Protect yourself again...

Page 90: ...their edge so that you do not touch the connector pins or conductor paths This way the discharge energy does not reach and damage the sensitive components Discharge your body electrostatically before you take a measurement at a module Do so by touching grounded metallic parts Always use grounded measuring instruments A 6 List of abbreviations Abbreviation Description DMZ Demilitarized Zone referre...

Page 91: ...Appendix A 6 List of abbreviations Getting Connected to MindSphere Getting Started 05 2018 91 ...

Page 92: ......

Page 93: ...l assets This can be anything such as a pump motor PLC an entire tool machine a production line a robot a crane a car a windmill and so on The data of an asset is collected and sent to MindSphere to make that data available for further processing and analytics Asset Identifier Asset Identifier is an identifier assigned by the manufacturer of the device to which MindConnect Nano will be connected A...

Page 94: ...can be monitored by MindSphere For example OPC UA Server S7 Event In Fleet Manager an event is a change of a datapoint state Events are used for the requests With a rule it is possible to define the request which will be created in MindSphere when the event is triggered Besides the monitoring rule a description of event e g The limit is exceeded this may indicate damage in the pump the resulting a...

Page 95: ...documentation MindSphere Launchpad MindSphere Launchpad is the entry point for Components as well as for available MindApps Online Offline Mode in Asset Manager Online indicates internet connection when the MindConnect Nano IoT2040 sends the data to the server Offline mode means the absence of the internet connection and the MindConnect Nano IoT2040 is no longer able to send data to the server Org...

Page 96: ...reshold edge trigger See also event request Timeseries Timeseries is a sequence of measurements which are produced by datasources over time Analysis and visualization tools e g Fleet Manager can retrieve collected timeseries and present it to the user after processing In Asset Manager the measurements that have to be collected can be specified User Management User Management is a Web Graphical Use...