9.1.2
Risk of explosion due to electrostatic charging
WARNING
Risk of explosion due to static charging
If you clean the machine with compressed air, plastic components may become statically
charged and create a potentially explosive atmosphere. An explosion can occur. This can
result in death, serious injury or material damage.
● Do not use compressed air to clean plastic parts in an explosive atmosphere.
● When cleaning the machine, make sure that the air in the vicinity of the motor is free of
gas and dust.
9.1.3
Inspections in the event of faults
Natural disasters or unusual operating conditions, such as overloading or short circuit, are
faults that overload the machine electrically or mechanically.
Immediately perform an inspection after such faults.
9.1.4
First inspection
Perform the following checks after approximately 500 operating hours or one year, whichever
comes first:
Table 9-1
Checks after installation or repair
Check
When the
motor is
running
At stand‐
still
The electrical parameters are maintained.
X
The permissible bearing temperatures are not exceeded.
X
The smooth running characteristics and machine running noise have not
deteriorated.
X
The motor foundation has no cracks and indentations. (*)
X
X
(*) You can perform these checks while the motor is at standstill or, if required, while running.
Further checks
Further checks may be required if so specified in supplementary instructions or in accordance
with the plant-specific conditions.
NOTICE
If you detect any deviations during the inspection, you must rectify them immediately. They
may otherwise damage the motor.
Maintenance
9.1 Inspection and maintenance
LOHER CHEMSTAR 1PS2
Operating Instructions 08/2016
87
Summary of Contents for LOHER CHEMSTAR 1PS2
Page 2: ...04 08 2016 11 45 V3 00 ...
Page 64: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS2 64 Operating Instructions 08 2016 ...
Page 74: ...Start up 7 8 Test run LOHER CHEMSTAR 1PS2 74 Operating Instructions 08 2016 ...
Page 84: ...Operation 8 11 faults LOHER CHEMSTAR 1PS2 84 Operating Instructions 08 2016 ...
Page 102: ...Maintenance 9 2 Corrective Maintenance LOHER CHEMSTAR 1PS2 102 Operating Instructions 08 2016 ...
Page 118: ...Service and Support LOHER CHEMSTAR 1PS2 118 Operating Instructions 08 2016 ...
Page 120: ...Technical data and drawings LOHER CHEMSTAR 1PS2 120 Operating Instructions 08 2016 ...
Page 142: ...Index LOHER CHEMSTAR 1PS2 142 Operating Instructions 08 2016 ...