X
X
Bearing canted
Properly install the bearing.
X
X
Insufficient bearing play
Contact the Service Center.
X Excessive bearing play
Contact the Service Center.
X
X
Bearing corroded
Replace the bearing. Check the seals.
X
Too much grease in bearing
Remove surplus grease.
X
Wrong grease in the bearing
Use the correct grease.
X Friction marks on raceway
Replace the bearing.
X Scoring (brinelling)
Replace the bearing. Avoid any vibration at standstill
8.11.5
Faults at the external fan
The following table shows the possible causes of and remedial measures for faults on forced-
ventilated machines.
Table 8-5
Cooling system faults
↓ High temperature rise with load
Possible causes of faults
Remedial measures
X Wrong direction of rotation of the external fan Check the electrical connections to the external fan.
X External fan is not running
Check the external fan and its connections.
X Reduced air flow
Check the air ducts; clean the machine.
Operation
8.11 faults
LOHER CHEMSTAR 1PS2
Operating Instructions 08/2016
83
Summary of Contents for LOHER CHEMSTAR 1PS2
Page 2: ...04 08 2016 11 45 V3 00 ...
Page 64: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS2 64 Operating Instructions 08 2016 ...
Page 74: ...Start up 7 8 Test run LOHER CHEMSTAR 1PS2 74 Operating Instructions 08 2016 ...
Page 84: ...Operation 8 11 faults LOHER CHEMSTAR 1PS2 84 Operating Instructions 08 2016 ...
Page 102: ...Maintenance 9 2 Corrective Maintenance LOHER CHEMSTAR 1PS2 102 Operating Instructions 08 2016 ...
Page 118: ...Service and Support LOHER CHEMSTAR 1PS2 118 Operating Instructions 08 2016 ...
Page 120: ...Technical data and drawings LOHER CHEMSTAR 1PS2 120 Operating Instructions 08 2016 ...
Page 142: ...Index LOHER CHEMSTAR 1PS2 142 Operating Instructions 08 2016 ...