Installing/connecting 

 

4.1 Installing and connecting the CP 1625 

CP 1625 / CP 1625Dev 
Operating Instructions, 04/2018, A5E43075902-AA 

21

 

Installing and connecting the CP 1625 

 

 

Note 
Installation only with power disconnected 
Opening the PC and inserting or removing submodules is only permitted when the power is 

disconnected. 

 

Proceed as follows when installing and connecting the CP 1625: 
1.

 

Turn off your PC and pull out the power cable connector from the socket. 

2.

 

Open the PC housing as described in your PC manual. 

3.

 

Remove the cover of a free PCI slot in your PC. 

4.

 

Take the CP 1625 out of the packaging. 

 

 

 

Note 
When handling the communications processor, make sure that you do not touch the 

connectors or the electronic components. 

 

5.

 

Insert the CP 1625 into the PCIe slot according to the instructions. Make sure that the  

CP 1625 is inserted securely and evenly in the slot socket. 

6.

 

Close the PC housing as described in your PC manual. 

7.

 

Insert the connecting cable (TP) into the corresponding socket on the front panel of the 

CP 1625. 

8.

 

Insert the power plug into the power socket again. 

9.

 

Switch on your PC. 

Passive network components 

You will find important notes on the use of passive network components in the document 

"Industrial Ethernet / PROFINET Passive network components" 

(

https://support.industry.siemens.com/cs/ww/en/view/84922825

).  

Siemens Automation Parts

Summary of Contents for CP 1625

Page 1: ..._____________ ___________________ SIMATIC industrial PC PC PROFINET IRT CP 1625 CP 1625Dev Operating Instructions 04 2018 A5E43075902 AA Preface Safety information 1 Product overview 2 Mounting 3 Installing connecting 4 Configuration 5 Technical specifications 6 Standards approvals and EMC guidelines A Siemens Automation Parts ...

Page 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Page 3: ...6ES7648 2CF10 1BA0 Scope of validity of the documentation This documentation is valid for the following products CP 1625 CP 1625Dev Conventions CP 1625Dev means that the section applies only to the CP 1625Dev CP 1625 includes the CP 1625 and the CP 1625Dev Notes Please also observe notes marked as follows Note Notes contain important information on the product handling the product or on part of th...

Page 4: ...s You will find this documentation on the Product Support pages on the Internet NET Industrial Ethernet PROFINET System Manual You will find detailed information on the structure of an industrial Ethernet network in this document Entry ID https support industry siemens com cs ww en view 27069465 SIMATIC PROFINET System Description Manual This provides you with basic knowledge of the following PROF...

Page 5: ...nd examples to solve your automation tasks as well as function blocks performance information and videos Services Information about Industry Services Field Services Technical Support spare parts and training offers Forums For answers and solutions concerning automation technology mySupport Your personal working area in Industry Online Support for messages support queries and configurable documents...

Page 6: ...tions processor CP 1625 12 2 3 1 Interfaces and display elements 12 2 3 2 Properties 13 2 4 Communications processor CP 1625Dev 14 2 4 1 Interfaces and display elements 14 2 4 2 Properties 18 3 Mounting 19 3 1 Installing the holding plate 19 4 Installing connecting 20 4 1 Installing and connecting the CP 1625 20 5 Configuration 22 6 Technical specifications 23 A Standards approvals and EMC guideli...

Page 7: ... be identified by the following label Strictly follow the guidelines mentioned below when handling modules which are sensitive to ESD Before working with modules with ESD you need to ensure that you are free of electrostatic charge e g by touching a grounded object All devices and tools must be free of static charge Always pull the mains connector and disconnect the battery before installing or re...

Page 8: ...s and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures e g firewalls and or network segmentation are in place For additional information on industrial security measures that may be implemented please visit https www siemens com industrialsecurity Siemens products and solution...

Page 9: ...X501 UART1 X602 Interface for PROFINET certification X2200 Jumper for selecting boot source X1600 Jumper for selecting restart behavior X2000 Jumper for selecting power supply source x Note If the consignment is incomplete contact your supplier or your local Siemens office 2 1 Hardware and software requirements Hardware requirement The CP 1625 requires a short PCIe slot with master capabilities fo...

Page 10: ...1625 CP 1625Dev 10 Operating Instructions 04 2018 A5E43075902 AA 2 2 View of front panel Connection elements The following figure shows the front panel of the communications processor CP 1625 Port 1 of the X1 interface Port 2 of the X1 interface ...

Page 11: ... circuiting the LAN ports If you accidentally short circuit the two LAN ports of the communications processor this leads to a malfunction of the network and the communications processor To restore the full scope of functions you may need to reset the communications processor or the Software Controller LEDs of the RJ45 sockets Two LEDs can be found in the frame of each RJ45 socket The green LED lig...

Page 12: ... 12 Operating Instructions 04 2018 A5E43075902 AA 2 3 Communications processor CP 1625 2 3 1 Interfaces and display elements Appearance The following figure shows the most important interfaces of the communications processor CP 1625 Figure 2 1 View of the CP 1625 interfaces ...

Page 13: ...net Real Time ASIC SOC 1 Two RJ45 sockets for connecting end devices or other network components Front LEDs on the RJ45 sockets for efficient self diagnostics of connection and data exchange Link and Activity LED Integrated 2 port real time switch Automatic hardware detection is supported Ethernet The CP 1625 is intended for operation in Ethernet networks It also has the following features Connect...

Page 14: ...ents Appearance The following figure shows the most important interfaces jumpers and LEDs of the communications processor CP 1625Dev X80 Connection for an external 24 V DC power supply X500 UART0 X501 UART1 X602 Interface for PROFINET certification X2200 Jumper for selecting boot source X1600 Jumper for selecting restart behavior X2000 Jumper for selecting power supply source Figure 2 2 CP 1625Dev...

Page 15: ...tgoing data RS232 interface RXD Connection for incoming data RS232 interface Figure 2 3 X500 X501 Interface X602 If PROFINET certification of a device based on CP 1625Dev is required the certification authority uses the XPLL_OUT signal The signal is available on the circuit board for measuring purposes The interface is designated with the number in the figure above Figure 2 4 X602 Signal Pin XPLL_...

Page 16: ...Dev connected CP 1625Dev external X1600 X2000 X2200 Interface jumper X1600 At interface X1600 you use the jumper to set whether the CP 1625Dev should perform a restart via the PCIe bus or be manually restarted The interface is designated with the number in the figure above Figure 2 5 X1600 Pin assignment Description Pins 1 and 2 Restart via PCIe bus Pins 2 and 3 Manual restart with external use of...

Page 17: ...xternal use of the CP 1625Dev NOTICE Damage to the IPC or the CP 1625Dev Damage can occur if the jumper is inserted incorrectly on the X2000 interface and the IPC is then connected to a 24 V DC power supply Set the position of the jumper on the X2000 interface according to the use of the CP 1625 Interface jumper X2200 At interface X2200 you use the jumper to set whether the SOC1 is to boot from NA...

Page 18: ...switch Automatic hardware detection is supported 24 V DC power supply for operation outside of the PC housing Two UART interfaces are available over the header Pushbutton for manually restarting the board Two LEDs on the board that signal an error or maintenance Error and Maintenance LED NAND flash SYNC Out signal available via the solder joint DDR2 memory technology up to 256 MB RAM External powe...

Page 19: ...environments with increased mechanical loads we recommend mounting of the holding plate included in the scope of delivery This improves the mechanical stability of the plug in connection You fasten the outgoing cables to the holding plate with cable ties Figure 3 1 Correct mounting of holding plate Siemens Automation Parts ...

Page 20: ...ation Before installing the CP in your PC read your PC manual for example the section Procedure for installing PCIe modules Observe the instructions described in the manual for your PC If available enable the plug and play mechanism in the BIOS of your PC Before installation make sure that the jumpers are set correctly on the CP 1625Dev You can find information on this in the section Interfaces an...

Page 21: ...625 out of the packaging Note When handling the communications processor make sure that you do not touch the connectors or the electronic components 5 Insert the CP 1625 into the PCIe slot according to the instructions Make sure that the CP 1625 is inserted securely and evenly in the slot socket 6 Close the PC housing as described in your PC manual 7 Insert the connecting cable TP into the corresp...

Page 22: ...unications processor CP 1625 is configured in the TIA Portal Requirements TIA Portal V15 incl Update 1 S7 1500 Software Controller CPU 1507S F V2 5 is installed on the IPC Reference You can find additional information on configuration in the TIA Portal and in the CPU 1505SP F CPU 1507S F Version 2 operating instructions http support automation siemens com WW view en 109740725 ...

Page 23: ...ces Connection to 10BaseT 100BaseTx RJ 45 connector 2 units Connection to PC PCI Express X1 V1 0a Plug Play Voltage Power supply PCI Express 3 3 VDC 9 Supply voltage externally via X80 rated voltage 19 2 V DC to 28 8 V DC Current consumption PCI Express voltage at 3 3 V Maximum 1 2 A External supply at 24 V Maximum 250 mA Permitted environmental conditions Operating temperature 0 C 45 C Transporta...

Page 24: ...d CP 1625Dev communications processor to a 24 V DC power supply this can result in undefined states Damage to the IPC and or the CP 1625Dev communications processor can occur as a consequence Do not connect a 24 V DC power supply to a plugged CP 1625Dev communications processor This product is intended for delivery with a UL listed power supply unit designated as Class 2 with 24 V DC 1 A rated val...

Page 25: ...ed approvals apply only when the corresponding mark is printed on the communications processor Recycling and disposal For environmentally friendly recycling and disposal of your old equipment contact a certified electronic waste disposal company and dispose of the equipment according to the applicable regulations in your country Siemens Automation Parts ...

Page 26: ...ectromagnetic Compatibility EMC Directive 2011 65 EU Restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS Directive The EC declarations of conformity are available for the responsible authorities at Siemens AG Digital Factory Factory Automation DF FA AS DH AMB Postfach 1963 D 92209 Amberg They are also available for download on the Siemens Industry Onl...

Page 27: ...the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Siemens AG is not responsible for any radio television interference caused by unauthorized modifications...

Page 28: ...on for CP 1625 https support industry siemens com cs ww en view 109756565 Korea Certificate KCC MSIP REM S49 PCCP Note that this device corresponds to limit class A in terms of the emission of radio frequency interference This device can be used in all areas except residential areas 이 기기는 업무용 A급 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다 Marking for the Eurasian Customs Unio...

Page 29: ...lating to electrical configuration EMC directive The communications processor meets the requirements of the EC Directive 2004 108 EC EMC directive Use in industrial environments The communications processor CP 1625 is designed for use in industrial areas It meets the following standards for this type of use Requirements for emitted interference EN 61000 6 4 Requirements for immunity to interferenc...

Page 30: ...tion 18 Installation 21 Interfaces 14 Jumpers 14 Power supply 18 Properties 18 Scope of delivery 9 Technical specifications 23 Writing conventions 3 D Delivery variants CP 1625 3 CP 1625Dev 3 E Electromagnetic compatibility EMC 29 EMC Electromagnetic compatibility 29 F Front panel Connection elements 10 RJ45 sockets 11 H Holding plate mounting 19 I Installation CP 1625 21 CP 1625Dev 21 Passive net...

Page 31: ...ocumentation 3 Scope of delivery CP 1625 9 CP 1625Dev 9 Specialist terms SIMATIC NET glossary 4 Standards 26 T Technical specifications CP 1625 23 CP 1625Dev 23 Electromagnetic compatibility EMC 29 Standards and approval 26 Trademarks 3 W Writing conventions 3 Siemens Automation Parts ...

Reviews: