23
VDT Interface for the MXL
STANDBY POWER
The MXL-VDT requires a standby power source in the event of the loss of primary input power (AC
mains.) Refer to Figure 3 below for the wiring diagram.
Figure 3
MXL-VDT Standby Power Wiring Diagram
NOTES:
1. All wires 14 AWG min, 600V insulation.
2. Wiring to the printer and PIM-1 must be 14 AWG min, 600V insulation
in conduit.
3. Use the UPS ICS Lifeline Model 9300057.
4. Standby Power Requirements: 120 VAC, 0.6A for 24 hours.
NOTES:
1. Refer to
PIM-1 Installation Instructions, P/N 315-091462
, for the
connection to MXL.
2. See
PIM-1 to MXL-VDT Minimum Cabling Requirements
table,
page 11, for specific cabling requirements.
3. AC power connection is 110 VAC, 60Hz.
4. Maximum cable distance from PIM-1 (P3) to MXL-VDT is 25
feet. The modules and cable must be in the same room.
5. MXL-VDT auxiliary and parallel ports may be connected to
UL-EDP listed printer which serves as an unsupervised
ancillary device only.
Figure 2
MXL-VDT Installation Diagram