Siemens CERBETUS PYROTRONICS VDT Operation And Installation Manual Download Page 1

Fire Safety

P/N 315-091734-9

Siemens Building Technologies, Inc.

8 Fernwood Road

Florham Park, New Jersey 07932

Siemens Building Technologies, Ltd.

2 Kenview Boulevard

Brampton, Ontario L6T 5E4 CN

CERBERUS PYROTRONICS

™

MODEL VDT
Interface for the

CERBERUS PYROTRONICS

™

 MXL

Operation and Installation Manual

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Summary of Contents for CERBETUS PYROTRONICS VDT

Page 1: ...ham Park New Jersey 07932 Siemens Building Technologies Ltd 2 Kenview Boulevard Brampton Ontario L6T 5E4 CN CERBERUS PYROTRONICS MODEL VDT Interface for the CERBERUS PYROTRONICS MXL Operation and Installation Manual Technical Manuals Online http www tech man com firealarmresources com ...

Page 2: ...Messages 3 List Software Versions 3 List XLD 1 Calibration Voltage 4 List XLD 1 ID Voltage 4 List XLD 1 2nd ID Voltage 4 List Air Sampling Smoke Percent 4 List Air Sampling Airflow Percent 4 List Air Sampling Alarm Trip Points 4 List Air Sampling Airflow Trip Points 4 List Percent Ft Sensitivity 4 List Percent Ft Pre Alarm 4 List Percent Ft Analog 5 List ASD Applications 5 List Disarmed Output Sta...

Page 3: ... 1 Point Annunciator PAX Lamp Test 9 Test Pre Alarm 9 Test ASD Devices 9 Set Commissioning Mode for Module 9 CMC Commissioning Mode Control 9 History Logging Off 9 History Logging On 10 Arm Disarm History Erasure 10 History Log Erase 10 MXL VDT 80 132 SETUP 10 MXL VDT 80 132 SETUP USING AUXILIARY OR PARALLEL PORT 13 CABLING REQUIREMENTS FOR AUXILIARY PORT TO PRINTER 16 RECOMMENDED PRINTER SETTINGS...

Page 4: ...llowed by the appropriate pass word If a Control command is entered before logging on MXL indicates that the log on is required NOTE Commands are NOT case sensitive CSG M Requirements NOTE CSG M does not allow this option to be unsupervised in an NFPA 72 Proprietary system To use the VDT interface set the printer option in the CSG M Network Map MKB subaddress to one of the following depending on t...

Page 5: ...ccustomed to XL3 commands LAL List Alarms LA Use the LAL command for a listing of current alarms At the command prompt type LAL followed by ENTER The events in the alarm queue are displayed on the VDT in the same format as the list alarms print item in the MXL menu See List Alarm in the MXL MXLV Manual P N 315 092036 Note that the XL3 command LA is honored for users accustomed to XL3 commands LSP ...

Page 6: ...d is honored for users accus tomed to XL3 commands LMT List Module Type Use the LMT command for a listing of module types in the system At the command prompt type LMT then press ENTER The types for all modules in CSG M are displayed on the VDT in the same format as they are in the List Module print item in the MXL menu See List Module in the MXL MXLV Manual P N 315092036 LDT m List Device Type Use...

Page 7: ...ist Air Sampling Airflow Percent Use the LAP command for a listing of Air Sampling airflow percent of scale values At the command prompt type LAP space and the NIM 1 ASP module number for which the list is needed Press ENTER The Air Sampling airflow percents for the selected module m are displayed on the VDT in the same format as they appear in the corresponding print item in the MXL menu LAT m Li...

Page 8: ...n that module the system will respond as follows Listing of Disarmed Input Points for Module 15 CRM4 NO ENTRIES Only default values found LCM List Modules in Commissioning Mode Use the LCM command to list the module s in the system that are currently in summarized commissioning mode At the command prompt type LCM Press ENTER The system lists the modules in commissioning mode as shown in the follow...

Page 9: ... The ALD 2Is loop network address of the input to be armed disarmed d The loop subaddress of the input to be armed disarmed x The desired arm disarm state of the input A Arm input D Disarm input Note that the XL3 command CO or COI m d x where m is the network ALD 2 loop d is the subaddress of the input point and x is the desired armed disarmed state is honored for users accustomed to XL3 commands ...

Page 10: ... command prompt type CAP space the module device number space and the desired ASD application apps Refer to Table 1 for a listing of ASD applications and abbreviations Press ENTER The new percent ft pre alarm settings are now in effect NOTE If the ASD application is changed while Test ASD is on the changes will not be effective until Test ASD is turned off TABLE 1 ASD SUBMENU ABBREVIATIONS VDT Abb...

Page 11: ...mber of events logged the history log type and the percent of history log used HAL hh mm ss mm dd yyyy Alarm History Use the HAL command for a list of the alarms recorded since the date shown in the command line If the date parameter is omitted the history log start date is used HSP hh mm ss mm dd yyy Supervisory History Use the HSP command for a list of the supervisories recorded since the date s...

Page 12: ...ng and posting a Trouble Out NOTES 1 When toggling between Testing Enabled and Testing Disabled there is a three minute time period that separates the two states 2 If Test ASD is actived and left alone the system will automatically disable the test time out after four hours SCM Set Commissioning Mode for Module Use the SCM command to set a particular module in commissioning mode At the com mand pr...

Page 13: ...istory log erasure At the command prompt type HAR Press ENTER The HAR command must be enabled before History log erasure can be made using the HER command In order to access this feature the History Option must be enabled in the CSG M and downloaded to the MXL A password is required for the HAR command HER History Log Erase Use the HER command to manually erase the History log The History Erase op...

Page 14: ...rformed by MXL TABS SETUP None required ANSWERBACK SETUP Do NOT alter data in this menu Data is preset at factory Altering this data results in VDT supervision errors ANSI SETUP Characteristic Setting Fkey Lock Off Feature Lock On KeyPad Numeric Cursor Keys Normal Xfer Term EOS Char Mode National Keys Typewriter VT100 ID VT100 Print National Send All Send Area Screen Print Area Screen Send Term No...

Page 15: ...Per CSG M default 1200 baud Main Data Parity Per CSG M default 8 data bits no parity Main Stop Bits Per CSG M default 1 stop bit Ignore 8th Bit On Main Rcv Hndsk None Main Xmt Hndsk None Comm Mode Full Duplex Disconnect 2 seconds Use the following minimum cabling requirements when connecting a supervised interactive terminal to an MXL System PIM 1 to MXL VDT 80 132 Minimum Cabling Requirements PIM...

Page 16: ...ff Off Warning Bell On On On Margin Bell Off Off Off Bell Sound 1 1 1 Block Term US CR US CR US CR Send ACK Off On On Monitor Mode Off Off Off MXL VDT 80 132 SETUP USING EITHER THE AUXILIARY OR PARALLEL PORT Use the following settings in the setup menu when installing an unsupervised VDT with an unsupervised printer The settings are given for several printers NOTE The CSG M selection for the termi...

Page 17: ... Aux Interface RS232 RS422 RS433 Printer Serial Serial Parallel DISPLAY SETUP Setting Generic Characteristic Texas Inst C Itoh Parallel TI 820KSR Cl 2500 Printer Columns Per CSG M 80 Per CSG M 80 132 Clear Off Off Off Lines Per preference 24 Per preference Pages 1 x lines 1 x lines 1 x lines Status Line Off Off Off Cursor Style Per preference Per preference Per preference Cursor On On On Screen Sa...

Page 18: ...EOS EOS EOS Cursor Keys Normal Normal Normal Char Mode National National National Keys Typewriter Typewriter Typewriter VT100 ID VT 100 VT 100 VT 100 Print National National National Send All All All Send Area Scroll Rgn Scroll Rgn Scroll Rgn Print Area Scroll Rgn Scroll Rgn Scroll Rgn Send Term None None None Print Term None None None Print Mode Bidirectional Auto Auto Auto Answerbk On On On P U ...

Page 19: ...round 7 GND 6 DSR 20 DTR 7 RTS 5 CTS 8 CTS 11 Restraint 4 RTS C ITOH CI 2500 PRINTER Function No Menu No Status 00 MODE 02 L DEC EMULATION 07 PRINTER ID 04 LEVEL 1 11 BUFFER 02 NORMAL 13 PW ON 01 ON LINE 14 DIRECTION 03 UNI DIR 15 WRAPAROUND 02 WRAP 17 AUTO CR 01 CR LF 22 AUTO LF 02 CR LF 23 CAN 01 NORMAL 32 GL GO 01 US ASCII 35 G3 01 US ASCII 41 RAM AREA 01 DATA BUF 81 OFF LINE STATE 01 ALL RECEI...

Page 20: ... in lines 001 112 TEXAS INSTRUMENTS TI 820KSR PRINTER Printer Settings Communication Settings See Manual Recommended 83 Transmit DC3 or Break on Printer Busy DC1 on ready 81 Enable recognition of device and format control commands from communication line DFC option required Transmit space parity reverse parity checkoff Set to agree with terminal auxiliary port settings Baud rate Set to agree with ...

Page 21: ... m S M L 3 F t f i h S 2 1 2 e p y T e l u d o M t s i L T M L 4 F t f i h S 2 1 2 y t i r u c e S t s i L C S L 0 1 F 2 1 2 s g n i t t e S y t i v i t i s n e S t s i L m S S L 5 F t f i h S 2 1 2 s e g a t l o V y t i v i t i s n e S t s i L m V S L m F L 7 F t f i h S 2 1 2 n o i s r e V e r a w t f o S t s i L W S L 2 1 2 s u t a t S t s i L T S L S L 6 F 2 1 2 y r o s i v r e p u S t s i L P...

Page 22: ... d n a 0 3 s n o i s i v e R L X M 0 0 3 s r o t c e t e d e k o m s I 2 D L A 3 w o L 2 2 w o L 1 3 w o L 0 3 _ i H 6 2 _ i H 5 1 _ i H 4 l a m r o N 3 r o f r e h g i h d n a 4 0 6 s n o i s i v e R L X M 4 0 6 s r o t c e t e d e k o m s 1 D L X 2 _ i H 5 1 _ i H 4 l a m r o N 3 1 w o L 2 d r o w s s a p t n e r r u c l e c n a c f f O g o L F O L 1 1 F t f i h S 2 1 2 d r o w s s a p r e t n e...

Page 23: ... m m a r g o r P v e R L X M m e t I u n e M L X M d n a m m o C d n a m m o C y e K n o i t c n u F y t i v i t c e f f E y t i v i t i s n e S t F t n e c r e P l o r t n o C x x d m S P C 0 0 7 r e b m u n e l u d o m m r o t c e t e d e k o m s f o s s e r d d a b u s d g n i t t e s t f y t i v i t i s n e s d e r i s e d x x n o I t f 7 1 6 o t o h P t f 0 4 5 m r a l a e r P t F t n e c r e...

Page 24: ...o t s i H y t i r u c e S y y y y d d m m s s m m h h C S H y r o t s i H t n e v E l l A y y y y d d m m s s m m h h E A H r u o h t r a t s h h e t u n i m t r a t s m m s d n o c e s t r a t s s s h t n o m t r a t s m m y a d t r a t s d d r a e y t r a t s y y y y t s e T p m a L X A P 1 D L X m T L X 4 0 6 m r a l A e r P t s e T d m E R P 0 7 r e b m u n e l u d o m m r o t c e t e d e k o ...

Page 25: ...nals TB1 8 and 9 are connected together on the PIM 1 2 The busy signal from the printer prevents the loss of characters if the printer falls behind Refer to the printer manual for the proper pin usually 11 TB1 3 or 20 TB1 9 Leave jumper G1 in place if the System printer is supervised Cut jumper G1 if the System has an unsupervised printer TB1 CONNECTIONS Technical Manuals Online http www tech man ...

Page 26: ...r Requirements 120 VAC 0 6A for 24 hours NOTES 1 Refer to PIM 1 Installation Instructions P N 315 091462 for the connection to MXL 2 See PIM 1 to MXL VDT Minimum Cabling Requirements table page 11 for specific cabling requirements 3 AC power connection is 110 VAC 60Hz 4 Maximum cable distance from PIM 1 P3 to MXL VDT is 25 feet The modules and cable must be in the same room 5 MXL VDT auxiliary and...

Page 27: ...s Building Technologies Inc 8 Fernwood Road Florham Park New Jersey 07932 Siemens Building Technologies Ltd 2 Kenview Boulevard Brampton Ontario L6T 5E4 CN Technical Manuals Online http www tech man com firealarmresources com ...