![Siemens ASIC SIM 1-2 Function Manual Download Page 51](http://html.mh-extra.com/html/siemens/asic-sim-1-2/asic-sim-1-2_function-manual_377074051.webp)
Application Examples
SIM 1-2
C79000-G8976-C215-01
51
4.2.3 External Dynamic Signal Evaluation
Description of the Dynamic Input Evaluation
The circuit below is an example of retrieving the useful signal from the collector
signal of the optocoupler transistor for the downstream communication controller in
galvanic isolation mode.
The two voltage dividers R2/R3 and R4/R5 move the working range of the
comparator to the middle of the SPC-4–2 supply voltage V
CC
. The difference
between the values of R2 and R4 results in an offset in the quiescent state. R6
brings about a reduction in amplitude and C2 a delay of the reference voltage in
the active state. The capacitor C1 decouples the supply voltage of the optocoupler
from the communication controller supply voltage V
CC.
Example of Demodulator Input Evaluation
+
-
5,6k
5,6k
68pf
27k
Ausgang Optokoppler
Referenzspannung
Ausgang Komparator
1
1
2
2
3
3
22k
R1
R2
R3
R4
R5
C1
Komp.1
C2
68k
68k
V
R6
1n
nach Koppelkondenstor C
5V
CC
TxSD
GND