FNo.Abbreviation Meaning
OpFtEIOT
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
205Flt.Rec.viaKBFault recording initiated via keyboard C
206Flt.Rec.viaPCFault recording initiated via PC interfC
244D Time=
Diff. time of clock synchronism
M
301Syst.Flt
Fault in the power system
CGC
302Fault
Flt. event w. consecutive no.
C
354>CB Aux.3p cl>CB aux. contact:3poles closed (series) IOT
356>Manual Close>Manual close
IOT
501Device FltDetGeneral fault detection of device
OT
502Dev. Drop-offGeneral drop-off of device
C
511Device Trip General trip of device
OT
524I/In=
Interrupted current (I/In)
C
545T-Drop
Time from fault detection to drop-off
546T-Trip
Time from fault detection to trip
561Manual Close Circuit breaker manually closed (pulse)C OT
605I1[%]=
Operat. meas. station 1 in %
M
606I2[%]=
Operat. meas. station 2 in %
M
607I3[%]=
Operat. meas. station 3 in %
M
608ID[%]=
Operat. meas. diff. current in %
M
609IR[%]=
Operat. meas. restr. current in %
M
655I1=
Operat. meas. station 1 in A
M
656I2=
Operat. meas. station 2 in A
M
657I3=
Operat. meas. station 3 in A
M
658ID=
Operat. meas. diff. current in A
M
659IR=
Operat. meas. restr. current in A
M
801Ñ/Ñtrip =
Temperat. rise for warning and trip
M
1000Trip No =
Number of trip commands issued
M
1007ÌI/In=
Accumulated interrupted curr. I/In
M
1156>CB Test
>CB test start
IOT
1174CB in Test
Circuit breaker test in progress
CG OT
1185CB Test 3p
Circuit breaker test: Trip 3pole
CG OT
1503>O/L block
>Block thermal overload protection
IOT
1504>O/L alarm
>Thermal O/L protection: alarm only
IOT
1505>O/L blo Trip>Block trip signal of thermal O/L prot. IOT
1511O/L Prot. offThermal overload prot. is switched off CG OT
1512O/L blocked Thermal overload protection is blocked CG OT
1513O/L active
Thermal overload protection is active CG OT
1515O/L Warn I
Thermal overload prot.: Current warningCG OT
1516O/L Warn Ñ
Thermal overload prot.: Thermal warningCG OT
1517O/L pickup Ñ Thermal overload prot.: Pick-up thermalCG OT
1521O/L Trip
Thermal overload protection trip
CG OT
2303>Backup block>Block back-up overcurrent time prot. IOT
2304>Back bloTrip>Block trip signal of back-up overcurr. IOT
2306>I>> block
>Block I>> stage of back-up overcurrentCG IOT
2307>I>/Ip block >Block I>/Ip stage of back-up overcurr.CG IOT
2401Backup off
Back-up overcurr. prot. is switched offCG OT
2402Backup block Back-up overcurrent prot. is blocked
CG OT
2403Backup activeBack-up overcurrent prot. is active
CG OT
2411Back Gen. FltBack-up overcurrent: Gen. fault det.
CG OT
2421Backup I>>
Back-up overcurrent: Fault det. I>>
C OT
2422Backup I>/Ip Back-up overcurrent: Fault det. I>/Ip C OT
2441Backup TI>> Back-up overcurrent: Time TI>> expired C OT
2442Backup TI>/TpBack-up overcurrent: Time TI>/Tp exp. C OT
2451Back Gen.TripBack-up overcurrent: General trip
C OT
3003>Diff block >Block differential protection
IOT
3005>Diff bloTrip>Block trip signal of diff. prot.
IOT
3015Diff off
Differential protection is switched offCG OT
3016Diff blocked Differential protection is blocked
CG OT
3017Diff active Differential protection is active
CG OT
¨¬¬¬¬©¬¬¬¬¬¬¬¬¬¬¬¬¬©¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬©¬¬©¬¬©¬©¬¬¬Á