Table 8-2
Process connections
Version
MAG 5100W (7ME6520)
MAG 5100W (7ME6580)
EN 1092-1
PN 10 (145 psi):
● DN 200 to 300 (8" to 12")
Flat face flanges
PN 10 (145 psi):
● DN 350 to 1200 (14" to 48")
Raised face flanges
PN 16 (232 psi):
● DN 50 to 300 (2" to 12")
Flat face flanges
PN 16 (232 psi):
● DN 350 to 1200 (14" to 48")
Raised face flanges
PN 40 (580 psi):
● DN 15 to 40 (½" to 1½")
Flat face flanges
Raised face
(EN 1092-1, DIN 3501 and BS4504
have the same mating dimensions)
PN 16 (87 psi):
● DN 1400 to 2000 (54" to 78")
PN 10 (145 psi):
● DN 200 to 2000 (8" to 78")
PN16 (232 psi):
● DN 65 to 600 (2½" to 24")
PN 40 (580 psi):
● DN 25 to 50 (1" to 2")
ANSI B16.5
Class 150 lb: ½" to 24"
Class 150 lb: 1" to 24"
AWWA C-207
Class D:
● 28" to 48", Flat face flanges
Class D:
● 28" to 78", Flat face flanges
AS4087
PN 16 (230 psi):
● DN 50 to 1200 (2" to 48")
PN 16 (230 psi):
● DN 50 to 1200 (2" to 48")
JIS B 2220:2004
K10 (1" to 24")
K10 (1" to 24")
Table 8-3
Rated operating conditions
Version
MAG 5100W (7ME6520)
MAG 5100W (7ME6580)
Ambient temperature
● Sensor
-40 to +70 °C (-40 to +158 °F)
-40 to +70 °C (-40 to +158 °F)
● With compact transmitter
MAG 5000/6000
2)
-20 to +60 °C (-4 to +140 °F)
-20 to +60 °C (-4 to +140 °F)
MAG 6000 I
-20 to +60 °C (-4 to +140 °F)
-20 to +60 °C (-4 to +140 °F)
Operating pressure [abs. bar]
1
DN 15 to 40 (½" to 1½")
0.01 to 40 bar (0.15 to 580 psi)
DN 50 to 300 (2" to 12")
3)
0.03 to 20 bar (0.44 to 290 psi)
DN 350 to 1200 (14" to 48")
0.01 to 16 bar (0.15 to 232 psi)
DN 25 to 50 (1" to 2")
0.01 to 40 bar (0.15 to 580 psi)
DN 65 to 1200 (2½" to 48")
0.01 to 16 bar (0.15 to 232 psi)
DN 1400 to 2000 (54" to 78")
0.01 to 10 bar (0.15 to 145 psi)
Enclosure rating
Standard
IP67 to EN 60529 / NEMA 4X/6 (1 mH
2
O
for 30 minutes)
IP67 to EN 60529 / NEMA 4X/6 (1 mH
2
O
for 30 minutes)
Option
IP68 to EN 60529 / NEMA 6P (10 mH
2
O
continuously)
IP68 to EN 60529 / NEMA 6P (10 mH
2
O
continuously)
Corrosive category
C4 according to ISO 12944-2
C4 according to ISO 12944-2
Technical data
8.1 MAG 5100 W
SITRANS FM MAG 5100 W
50
Operating Instructions, 01/2020, A5E03063678-AC