Technical specifications
Power supply via optional power sup‐
ply adapter
12 to 24 VDC (9.6 to 28.8 VDC)
100 to 240 VAC
Fusing
2.5 A / 24 VDC
1 A / 48 VDC PoE
Current consumption
At 12 ... 24 VDC / max.
1400 to 700 mA
At 240 VAC / max
264 to 144 mA
Effective power loss
At 12 ... 24 VDC / typical
15 W
Permitted ambient conditions
Ambient temperature
Operation with 100 ... 240 VAC
You should also note the temperature
ranges specified in the approvals.
-40 °C to +60 °C
Maximum ambient temperature dur‐
ing operation
With SFP variants depends on plug-in transceiver:
SFP992-1
+60 °C
SFP992-1LD
+55 °C
SFP992-1LH
+50 °C
SFP992-1LH+
+50 °C
SFP992-1ELH
+45 °C
Ambient temperature
During storage
-40 ℃ to +70 °C
During transportation
-40 °C to +70 °C
Relative humidity
During operation
≤ 95% at 25 °C, no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. 60 °C am‐
bient temperature
Contaminant concentration
According to IEC 60721
Degree of protection
IP code
IP65
Dimensions and weight
Dimensions
W x H x D
251 x 251 x 72 mm
Weight
Without power supply adapter
2.24 kg
With power supply adapter 12 - 24 VDC 2.4 kg
With power supply adapter 100 ...
240 VAC
2.4 kg
Installation options
Direct
• Wall mounting
With additional holding plate
• Mast mounting
– Minimum mast diameter: 44 mm
– Maximum mast diameter 178 mm
• Mounting on a DIN rail
• Mounting on an S7-300 standard rail
Mean time between failure (MTBF)
At 40 °C ambient temperature
36 years
Technical specifications
9.2 SCALANCE W786-2
SCALANCE W786-x
Operating Instructions, 12/2021, A5E03678337-14
77
Summary of Contents for 6GK5786-1FC00-0AA0
Page 8: ...Introduction SCALANCE W786 x 8 Operating Instructions 12 2021 A5E03678337 14 ...
Page 10: ...Safety notices SCALANCE W786 x 10 Operating Instructions 12 2021 A5E03678337 14 ...
Page 66: ...Maintenance and cleaning SCALANCE W786 x 66 Operating Instructions 12 2021 A5E03678337 14 ...
Page 82: ...Dimension drawings SCALANCE W786 x 82 Operating Instructions 12 2021 A5E03678337 14 ...
Page 84: ...Certification SCALANCE W786 x 84 Operating Instructions 12 2021 A5E03678337 14 ...