3. Push in the SCALANCE W786 until it engages in the notches at the lower edge of the
mounting plate (position C in the figure above).
'
Figure 5-13
Screwing a SCALANCE W786 to a mounting plate
4. Screw the SCALANCE W786 using the three M4 screws supplied with the mounting plate
(position D in the figure above), tightening torque 1.8 Nm.
Procedure for removing the device
Follow the steps below to remove a SCALANCE W786 from a mounting plate:
1. Loosen the screws between the SCALANCE W786 and mounting plate.
2. Using a screwdriver or similar tool, press down the two lugs on the lower edge of the
mounting plate (position C in the first figure in this section) and release the SCALANCE W786
from the recesses.
3. Pull out the lower edge of the SCALANCE W786 to the front and then release it from the two
clips on the mounting plate (position B in the first figure in this section).
Installation and removal
5.5 Mounting with mounting plate
SCALANCE W786-x
Operating Instructions, 12/2021, A5E03678337-14
45