How to fit a power supply adapter
The following figure shows how a power supply adapter is fitted:
12 - 24 V
110 - 230 V
L1 M1 M2 L2
L N PE
B
A
A
Securing screw
B
Pull-out loop
Figure 6-5
Fitting a power supply adapter
Follow the steps below to fit and connect a power supply adapter:
1. Fit the power supply adapter in the SCALANCE W786 as shown in the figure above.
– The connector on the rear of the power supply adapter must engage fully in the socket of
the housing.
– The entire rear surface of the power supply adapter must make contact with the inner
surface of the SCALANCE W786.
2. Connect the power supply adapter and the SCALANCE W786 using the screw (position A)
that ships with the power supply adapter.
3. Connect the cable for the power supply. The assignment of the terminals is shown above.
4. Secure the power supply cable with a strain relief clamp. For more detailed information on
this topic, refer to the section "Connecting the cables".
Connecting up
6.5 Connecting the power supply adapter
SCALANCE W786-x
60
Operating Instructions, 12/2021, A5E03678337-14
Summary of Contents for 6GK5786-1FC00-0AA0