3 FM-STEPDRIVE specifications
02.05
© Siemens AG 1998 All Rights Reserved
3-2
FM-STEPDRIVE/SIMOSTEP (FB)
3.1 Electrical
data
Mains connection
Mains voltage
115 V or 230 V AC
Tolerance: -20% / +15%
Frequency range: 47 Hz to 63 Hz
External back-up fuse
16 A max. ("K" or "C" characteristic)
Input current
8 A max. at 115 V/4.5 A at 230 V
Starting current
75 A max.
Mains buffering time
> 10 ms at motor standstill
Maximum power loss
80 W
Intermediate circuit
connection
Intermediate circuit voltage
160 V to 485 V DC
Open-close cycle (during operation and after fault rectification)
> 5 s
Motor connection
Phase current
1.7 A to 6.8 A
6.8 A max. at an ambient temperature of 50°C
and vertical mounting position
4.8 A max. at an ambient temperature of 60°C
and vertical mounting position
4.8 A max. at an ambient temperature of 40°C
and horizontal mounting position
Motor voltage
3 x 325 V (connected to mains)
Motor cable
Trailing cable with double shield 3 x 1.5 CC
Length
50 m max.
Wire cross-section
3 x 1.5 mm
2
Summary of Contents for 1FL3041-0AC31-0BJ0
Page 2: ......
Page 6: ...II ...
Page 8: ...IV ...
Page 9: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 1 1 Overview 1 ...
Page 11: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 2 1 Functional description 2 ...
Page 25: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 5 1 Mounting 5 ...
Page 39: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 7 1 Setup 7 ...
Page 45: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 9 1 SIMOSTEP specifications 9 ...
Page 58: ......
Page 59: ......